8
1.
Position suction cup.
2.
Hot-air melts solder.
3.
IC pops up automatically.
Edit Profile
This option allows you to edit or create a profile.
First , you must select the profile to edit and then modify the points that make up the profile.
Each profile is composed of 9 points, each point is formed by three parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the profile by selecting “-----” in the time parameter.
It should be taken into account that the regulation range permitted by the station is between 150°C
and 450°C, whereby it is not possible to create temperature ramps between room temperature
(Toff) and 150°C.
The station can store up to 25 temperature profiles.
The first three profiles are edited as an example.
Copy Profile
This option allows you to copy a profile.
You must select the profile source and the destination profile where it will be copied.
Delete Profile
This option will allow you to delete a profile previously selected.
Process Control
Desoldering Procedure