![jbc JT-QD Manual Download Page 5](http://html1.mh-extra.com/html/jbc/jt-qd/jt-qd_manual_3640171005.webp)
Temp
º
C
º
C
Program 8
380
Air
100%
Time 125s.
Main menu
1 Reset station
2 Station Settings
3
Program Settings
4 Counters
5 Program version
Exit
Station Settings
Program Settings
Edit Program
Edit Program 1
1 Temp unit
Celsius
2
Maximum temp 450
0
C
3
Minimum temp T OFF
4 Fix temp -----
5 Temp Adjust + 0
0
C
6 Max air 100%
7 Min air 10%
8 Fix air -----
1 Programs OFF
2 Edit program
3
Copy program
4 Delete program
Back
Select
Program
Step
1
Time
30
Temp 300
Air
100
º
C
º
C
1
Exit
Counters
1 Station ON hours
0
2 Works hours 0
3
Works cycles 0
Back
9 Time to stop 120 sec
10 Stand/Pedal Stand
Autostart OFF
11 Beep ON
12 Pop up ON
13 Change PIN
8
9
Decrease program
number
Increase program
number
Selected program
Current temperature
Selected air flow
Graph of selected
program
Remaining time
Program Mode
Program Options
Edit Program
This option allows you to edit or create a program.
First, you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting “-----” in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C, whe-
reby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and its destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
* Selecting Minimum Temp as
“T OFF”, the air blows at room
temperature.
Menu Screen
Original PIN: 0105
8
www.jbctools.com
9