jbc JT-QD Manual Download Page 5

Temp 

º

C

º

C

Program 8

380

Air 

100%

Time  125s.

Main menu

1    Reset station
2   Station Settings

3

   Program Settings

4   Counters

5    Program version

Exit

Station Settings

Program Settings

Edit Program

Edit Program 1

1     Temp unit

                

 Celsius

  

 Maximum temp     450

0

C

3

    Minimum temp         T OFF

4   Fix temp                        -----

5    Temp Adjust              + 0

0

C

6    Max air                        100%
7    Min air                             10%
8    Fix air                              -----

1     Programs OFF
2    Edit program

3

    Copy program

4    Delete program

Back

Select

Program

Step 

1

Time 

30

Temp  300
Air 

100

º

C

º

C

1

Exit

Counters

1       Station ON hours  

      

            0

2      Works  hours                                0

3

     Works cycles                      0

Back

9    Time to stop          120 sec
10  Stand/Pedal              Stand
       Autostart                        OFF
11   Beep                                     ON

12   Pop up                                 ON
13   Change PIN

8

9

Decrease program 

number

Increase program 
number

Selected program

Current temperature

Selected air flow

Graph of selected 

program

Remaining time

Program Mode

Program Options

Edit Program

This option allows you to edit or create a program. 
First, you must select the program to edit and then modify the points that make up the program. 
Each program is composed of 9 points, each point consisting of 3 parameters: 
 

1. Time (seconds) 

 

2. Temperature (°C / °F) 

 

3. Flow rate (%)

You can delete the last point of the program by selecting “-----” in the time parameter. 

It should be taken into account that the regulation range permitted by the station is 150-450°C, whe-
reby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.

The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.

Copy Program

This option allows you to copy a program. 
You must select the program source and its destination (where it will be copied).

Delete Program

This option will allow you to delete a previously selected program.

* Selecting Minimum Temp as 
“T OFF”, the air blows at room 
temperature.

Menu Screen

Original PIN: 0105

8

www.jbctools.com

9

Summary of Contents for JT-QD

Page 1: ...English 3 Page www jbctools com Hot Air Station without extractor desk Ref JT QD www jbctools com Deutsch 18...

Page 2: ...er Cord 1 unit Ref 0009417 100V 120V 0009401 230V Hot Air Station without extractor desk Ref JT QD Heater hose set 1 unit Ref JT T1A 100V 120V JT T2A 230V JTE Control Unit 1 unit Ref JTE 1D 120V JTE 2...

Page 3: ...d from the stand Press the Pedal to blow hot air and release to stop The P 005 Pedal is not supplied with this station See our website 4 5 Another connectable tool Precision Heater hose set Ref TE TB...

Page 4: ...lat mm mm A x B mm 1 Push the nozzle tab inwards with a screwdriver or flat nosed pliers 2 Insert the nozzle into the JT TA Heater again Turn the tool off and handle with care The heating element and...

Page 5: ...ns Edit Program This option allows you to edit or create a program First you must select the program to edit and then modify the points that make up the program Each program is composed of 9 points ea...

Page 6: ...T Handle Ref JT A 1 Ensure that the tool is turned off 2 Use a spanner to unscrew the connecting nut 3 The tube end of the new heater must be inserted so that the longitudinal rib fits into the groove...

Page 7: ...eedles Set Ref 0861660 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fuse holder and replace it in the station Fuse holder Fuse h...

Page 8: ...hich can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabilities or lack of experience provided that they have be...

Page 9: ...ewicht 6 7 kg 14 7lb Abmessungen 148 x 184 x 140 Nennleistung 700 W Temperaturauswahl Raumtemperatur 150 C bis 450 C 300 F bis 840 F K hlmodus T Aus Benutzt als Luftstrom mit Raumtemperatur Umgebungsb...

Page 10: ...tlinie 2002 96 EC m ssen elektronische Ger te am Ende ihrer Lebensdauer eingesammelt und einem autorisierten Recyclingbetrieb zugef hrt werden 0016476 1015 www jbctools com Warranty JBC s 2 year warra...

Reviews: