Glass Solder Collector Cleaning
1. Removing the lid
3. Inserting the glass solder collector
Check filter
Lid
Check
internal joint
2. Cleaning
Check the filter and replace it if it is dirty
or damaged.
Remove the coil and clean the inside of the
glass solder collector with the cleaning stick.
The lid must be unscrewed with the DR560 in
a vertical position.
The glass solder collector must be inserted
with coil filter in place, positioned between the
2 lines marked.
Then the whole unit must be closed by
screwing the lid.