background image

350

ºC

Port

1

Power

45%

Temp levels

T245

250

350

380

19:29

Port

1

T245

19:29

Sleep

Tool in the stand
Actual Temp. 180º
Delay to hibernation: 29:30

Port

1

T245

19:29

Hibernation

Actual Temp. 25ºC

Peripherals

19:29

Pedal

PD_a

Module

MSE

Pedal

PD_a
PD_b

None

Peripherals

19:29

Pedal

PD_a

Module

MSE

Peripherals

19:29

Pedal

PD_a

Function

Extractor

Mode

released

Minimum time

0 sec

Back

Peripherals

Port 2-PA

Port 2-PA

Port 2-PA

Port 2-PA

19:29

Pedal

None

Module

None

Module

MSE_a

None

Menu Options

Station 
Information

Power 
Indicator

Tool
in use

DDE Work Display

Status Bar

DDE offers an intuitive user interface which provides quick access to station parameters.

Default PIN: 0105

Change 
Port

Displayed if 
Temperature 
Levels are 
Activated

Station

Tools

Counters

Reset

Language

Set the station 
parameters

Set the tool 
parameters

Display the hours 
worked in each cycle

It is possible to 
choose the language 
from a list

Station troubleshooting available on the product page at www.jbctools.com

Troubleshooting

Restore station 
parameters to default 
values

5

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

Summary of Contents for DDE

Page 1: ...INSTRUCTION MANUAL DDE 2 Tool Control Unit...

Page 2: ...y reading Packing List The following items are included This manual corresponds to the following reference DDE 9C 100 V DDE 1C 120 V DDE 2C 230 V Power Cord 1 unit Ref 0024077 100V 0023717 120V 002408...

Page 3: ...ng Iron ADS Stand for T210 T245 Handles DR560 Desoldering Iron T245 General Purpose Handle DDE 2 Tool Control Unit Module Cable Ref 0024228 Stand Cable Ref 0024227 MSE Electric Desoldering Module for...

Page 4: ...ering or desoldering needs Modular System Peripherals Control Unit Stand Tool Cartridge Range MSE MVE MNE P405 DDE ADS T210 C210 T245 C245 T470 DNS T210N C210 T245N C245 APS AP250 C250 AMS AM120 C120...

Page 5: ...ool in use DDE Work Display Status Bar DDE offers an intuitive user interface which provides quick access to station parameters Default PIN 0105 Change Port Displayed if Temperature Levels are Activat...

Page 6: ...g ramp up rate of the tool to gradually increase the temperature of the component through all the phases of the soldering process Up to 25 fully con gurable soldering pro les can be stored System Noti...

Page 7: ...9 29 Pedal PD_a Module MSE Peripherals 19 29 Pedal PD_a Function Extractor Mode released Minimum time 0 sec Back Peripherals Port 2 PA Port 2 PA Port 2 PA Port 2 PA 19 29 Pedal None Module None Module...

Page 8: ...5 C Peripherals 19 29 Pedal PD_a Module MSE Pedal PD_a PD_b None Peripherals 19 29 Pedal PD_a Module MSE Peripherals 19 29 Pedal PD_a Function Extractor Mode released Minimum time 0 sec Back Periphera...

Page 9: ...are clean so that the station can detect the tool s status Maintainthetipsurfacecleanandtinnedbefore storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder...

Page 10: ...at can cause inflammable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy...

Page 11: ...Notes 11 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm...

Page 12: ...Notes 12...

Page 13: ...Notes 13 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm...

Page 14: ...Notes 14...

Page 15: ...0 F Idle Temp Stability still air 1 5 C 3 F Meets and exceeds IPC J STD 001F Temp Accuracy 3 using reference cartridge Temp Adjustment 50 C 90 F Through station menu setting Tip to Ground Voltage Resi...

Page 16: ...anty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be vali...