background image

www.jbctools.com

0008865-1215

BT-1A 

120V 50/60Hz. Input fuse: 2A. Output: 24V

BT-2A 

230V 50/60Hz. Input fuse: 1A. Output: 24V

BT-9A 

100V 50/60Hz. Input fuse: 2A. Output: 24V

-  Weight: 2.6 Kg (5.7 lb)
-  Dimensions: 162 x 153 x 115 mm
-  Power: 75W
-  Temperature range: 100-450°C (200-850 ºF) (±5%)

Complies with CE standards
ESD protected housing “skin effect”

Warranty

JBC’s 2 year warranty covers this equipment against 
all manufacturing defects, including the replacement of 
defective parts and labour.
Warranty does not cover product wear due to use or 
mis-use. 
In order for the warranty to be valid, equipment must 
be returned, postage paid,  to the dealer where it was 
purchased.

This product should not be thrown in the garbage. 
In accordance with the European directive 2012/19/EU, electronic equipment at the end of their life 
must be collected and returned to an authorized recycling facility.

Specifications

Summary of Contents for BT-A

Page 1: ...Soldering Station Ref BT A www jbctools com ...

Page 2: ...BT 9A 100V Brass Wool 1 unit Ref CL6210 General Purpose Handle 1 unit Ref T245 A Cartridges 2 units Ref C245906 x1 C245907 x1 Features Cable collector Quick Tip Changer Tip Cleaning System Stand Yellow LED SLEEP Green LED IN USE Dial Main switch Fuse Power Socket Equipotential connection General Purpose Handle Ref T245 A www jbctools com Soldering Station Ref BT A www jbctools com ...

Page 3: ...ed with 3 m For general use Works with C245 Cartridge range Compatible Handles Soft foam Ref 0016057 Non slip soft touch Blue grip to easily distinguish it from other handles Put the slip on tabs into the new grip Slide the grip with the tabs onto the handle To remove the tabs hold the grip and pull tabs new grip General Purpose Handle Ref T245 A Note All models are supplied with a 1 5 m cable Eas...

Page 4: ...continually in a overloaded condition for a period of time the system will stop and both leds will flash simultaniusly Switch station off and on to reset and review the soldering application Yellow LED SLEEP Green LED IN USE Dial The original parameters of control unit can be modified using the AC console It is necessary to connect the console AC with software revision 7 0 or later to the BT in or...

Page 5: ... must be plugged into approved bases Be sure that it is properly grounded before use When unplugging it hold the plug not the wire Do not work on electrically live parts The tool should be placed in the stand when not in use in order to activate the sleep mode The soldering tip the metal part of the tool and the stand may still be hot even when the station is turned off Handle with care including ...

Page 6: ...10 11 Exploded View www jbctools com ...

Page 7: ...BC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In accordance with the European directive 20...

Reviews: