6
C a r t r i d g e a n d
electric connection
screw
WARNING: It is esential
to tighten this screw for
the tool to function.
Guide tube screw
5
Guide tube
8 - 10 mm
Alignment
4
1
ENGLISH
For a proper installation, please proceed as follow:
1
. Place the control in the position showed in the
graphic in order to open the dragging mechanism.
2
. Loosen the solder reel guide screws of the
control unit.
3
. Place the tubes and guides set in the control
unit. Note: with the
0,4 - 0,5
ø
guide set is necessary
to extract the wire of protection.Tighten the screws.
Guide sets
There are 4 guide sets, for the following solder
thread diameters:
-
0,4 - 0,5
ø
Ref. 0002399
-
0,6 - 0,8
ø
Ref. 0002402
-
0,9 - 1
ø
Ref. 0002401
-
1,1 - 1,5
ø
Ref. 0002843
Each set is supplied with 2 thread guides, the
leading tube and the exit guide in the iron.
4
. Place the solder feed handpiece.
¡Warning!
As a safety measure and in order to avoid burns,
when the cartridge is manipulated you must switch
off the station or disconnect the solder feed
handpiece. Take into account that it only takes a
few seconds to reach the working temperature.
5
. Place the guide tube for the solder threat in the
solder feed handpiece. You must leave a distance
between 8-10mm from the tip of the cartridge and
the end of the guide tube end. Tighten the screw of
the guide tube.
6
. Point the tip of the cartridge to the solder guide
tube exit. Tighten the cartridge screws.
Important.
-
It is essential to insert the cartridge till the
end for a good connection. Take the mark
as reference.
3
3
1
1
2
2