THEATRE SPOT 500W + 1000W

Thank you for buying this JB Systems

®

product. To take full advantage of all possibilities and for your own

safety, please read these operating instructions very carefully before you start using this unit.

FEATURES

This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.

This device has been designed to produce decorative effect lighting and is used in light show systems.

Theatre spotlight

500W version with GY 9,5 lamp socket

1000W version with GX 9,5 lamp socket

Equipped with PC-Antihalo lens

Free Fresnel lens included.

Accurate focusing system with endless screw system.

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.

Important:

This device left our factory in perfect condition and well packaged. It is absolutely necessary

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.

Check the contents:

Check that the carton contains the following items:

Operating instructions

Theater projector

Filter frame

Fresnel lens

SAFETY INSTRUCTIONS:

CAUTION:

To reduce the risk of electric shock, do not remove the top cover.

No user-serviceable parts inside. Refer servicing to qualified service
personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use
or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this
appliance.

This symbol means: indoor use only.

This symbol means: Read instructions.

This symbol determines: the minimum distance from lighted objects. The minimum distance between
light-output and the illuminated surface must be more than 1 m for the 500W version and more than
2m for the 1000W version.

To protect the environment, please try to recycle the packing material as much as possible.

A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears
after some minutes.

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

CAUT ION

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

2/30

THEATRE SPOT 500W + 1000W

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign
object enters the unit, immediately disconnect the mains power.

Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture
must be fixed at least 50cm from surrounding walls.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.

The units’ surface temperature may reach up to 125°C for the 500W version and 160°C for the 1000W
version. Don’t touch the housing with bare hands during its operation.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Allow the device about 10 minutes to cool down before replacing the bulb or start servicing.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The power cord should always be in perfect condition: switch the unit immediately off when the power cord
is squashed or damaged.

Never let the power-cord come into contact with other cables!

This fixture must be earthed to in order comply with safety regulations.

Don’t connect the unit to any dimmer pack.

Always use an appropriate and certified safety cable when installing the unit.

In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no
user serviceable parts inside.

Never

repair a fuse or bypass the fuse holder.

Always

replace a damaged fuse with a fuse of the same

type and electrical specifications!

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

The housing and the lenses must be replaced if they are visibly damaged.

Please use the original packing when the device is to be transported.

Due to safety reasons it is prohibited to make unauthorized modifications to the unit.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons suffering

from epilepsy.

DESCRIPTION:

1. Handle
2. Hanging bracket
3. Filter frame
4. Barn door support
5. Knob to open the lamp compartment
6. Mains cable
7. fixing point for safety cable
8. Screw for focusing system

Summary of Contents for Theatre Spot 500W

Page 1: ...tion or publication of the content in any manner without express permission of the publisher is prohibited THEATRE SPOT 500W 1000W Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...ture CAUTION ENGLISH OPERATION MANUAL JB SYSTEMS 2 30 THEATRE SPOT 500W 1000W To avoid condensation to be formed inside allow the unit to adapt to the surrounding temperatures when bringing it into a...

Page 4: ...of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10times the device s weight Always use a certifi...

Page 5: ...des spectacles lumineux Spot de th tre Version 500W avec douille GY 9 5 Version 1000W avec douille GX 9 5 Pourvu d une lentille PC Antihalo Lentille Fresnel incluse dans le prix Syst me de mise au po...

Page 6: ...iter tout choc lectrique ne pas ouvrir l appareil En dehors des ampoules et du fusible principal il n y a pas de pi ces pouvant tre chang es par l utilisateur l int rieur Ne jamais r parer ou court ci...

Page 7: ...as toucher la coque mains nues en cours de fonctionnement D branchez syst matiquement l appareil s il n est pas utilis pour une p riode prolong e ou avant de changer une ampoule ou d effectuer des op...

Page 8: ...rdwijnt na een paar minuten Stel dit apparaat niet bloot aan regen of vocht dit om het risico op brand en elektrische schokken te voorkomen Om de vorming van condensatie binnenin te voorkomen laat het...

Page 9: ...g Verplaats de lampsokkel terug naar zijn originele positie Sluit het lampcompartiment met de schroef Klaar OPHANGEN VAN HET APPARAAT Belangrijk De installatie van het toestel mag uitsluitend door bek...

Page 10: ...00W 1000W Vielen Dank dass Sie sich f r den Erwerb dieses JBSystems Produkt entschieden haben Bitte lesen sie diese Bedienungsanleitung sorgf ltig vor der Inbetriebnahme durch zur vollen Aussch pfung...

Page 11: ...rwenden um Sch den am Ger t zu vermeiden Aus Sicherheitsgr nden d rfen an dem Ger t keine unbefugten Ver nderungen vorgenommen werden Wichtiger Hinweis Nicht direkt in die Lichtquelle blicken Ger t ni...

Page 12: ...mgehend mit ihrem H ndler in Verbindung setzen WichtigerHinweis Nicht direkt in die Lichtquelle blicken Ger t nicht verwenden wenn sich Personen im Raum befinden die unter Epilepsie leiden WARTUNG UND...

Page 13: ...lluvia o humedad Para evitar que se forme condensaci n en el interior permita que la unidad se adapte a las temperaturas circundantes cuando la lleve a una habitaci n c lida despu s de transporte Con...

Page 14: ...taje desmontaje y reparaci n Coloque la instalaci n en un sitio bien ventilado lejos de cualquier material inflamable y o l quidos La instalaci n debe ser fijada al menos a 50cm de los muros circundan...

Page 15: ...s pelo fabricante Esta unidade destina se a produzir efeitos luminosos decorativos e utilizada em sistemas de espect culos de luz Projector de teatro Vers o de 500W com suporte de l mpada GY 9 5 Vers...

Page 16: ...nem tente operar a unidade sem fus vel Substitua sempre um fus vel danificado por outro com as mesmas caracter sticas Em caso de problemas s rios de funcionamento interrompa a utiliza o da unidade e...

Page 17: ...manuten o Caso a unidade apresente problemas s rios de funcionamento interrompa a utiliza o da unidade e contacte o seu revendedor imediatamente Importante Nunca olhe directamente para a luz N o utili...

Reviews: