background image

ENGLISH 

 

USER MANUAL

 

 
JB SYSTEMS® 

12/12 

SMOOTH SCAN-3 Mk2 LASER 

 

MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

  Clean the external optics at least once every 30 days.  

  Clean the internal optics at least every 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

Mains Input: 

AC 100~240V, 50/60Hz  

Fuse: 

250V 1A slow blow (20mm glass) 

Total Power consumption:

 

13W 

Sound Control: 

Internal microphone 

DMX connections: 

3pin XLR male / female

 

 

DMX channels: 

1 or 17 channels 

DMX starting address:

 

001 

 512 

Laser Power:

 

50mW Green CW laser (

λ = 515nm) 

 

 

100mW Red CW laser (

λ = 650nm) 

 

Laser radiation class:

 

3B 

Beam diameter @ aperture:

 

<5mm 

Divergence (each beam)

 

<2 mrad 

Divergence (total output)

 

<90° 

Scanner speed:

 

15kHz 

Working temperature:

 

10°C to 40°C 

Laser Safety Standard:

 

EN/IEC 60825-1:2014

 

Size:

 

see picture below  

Weight:

 

1.35kg 

 

 

 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website : www.jb-systems.eu

 

Summary of Contents for Smooth Scan-3 MK2 Laser

Page 1: ......

Page 2: ......

Page 3: ...channel for easy operation or 17 channels for full control Standalone sound activated internal mic or automatic IR remote infrared remote control Master slave wonderful synchronized shows Built in mic...

Page 4: ...s Don t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should no...

Page 5: ...om a laser beam it can still potentially injure or blind you or your audience Even very small amounts of laser light are potentially hazardous even at long distances Never look into the laser aperture...

Page 6: ...EBOLT used to attach a safety cable when the unit is rigged see paragraph overhead rigging 10 INTERLOCK input REMOTE used to connect the optional emergency stop switch see picture When you push this s...

Page 7: ...s may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations...

Page 8: ...lowing Sop Aut Aup 17C 1C Sla or REM Now use the UP or DOWN buttons to select o Aut Automatic shows in RGY colors o Au1 Automatic shows in red color o Au2 Automatic shows in green color o Au3 Automati...

Page 9: ...unning show MUSIC Sound activated show the blue is flashing when the sound is detected Sound sensivity In sound activated mode press music B 1to9 to change the sensitivity settings COLOR CHANGING To c...

Page 10: ...he chain needs to have its proper starting address so it knows which commands from the controller it has to decode 1 CHANNEL DMX CONFIGURATION OF THE LASER position DMX value function remarks 8 240 25...

Page 11: ...g Speed CH6 Zooming 000 127 100 128 169 Zooming IN 170 209 Zooming OUT 210 255 Alternately Zooming CH7 zoom speed 000 255 Fast to slow CH8 X axis rolling 000 127 0 128 191 Clockwise rolling 192 255 An...

Page 12: ...10 12 SMOOTH SCAN 3 Mk2 LASER Pattern settings Press the FUNC button until the display shows Press up or down until the laser shows the Y arrow axis on the top and X arrow axis on the right Then press...

Page 13: ...ENGLISH USER MANUAL JB SYSTEMS 11 12 SMOOTH SCAN 3 Mk2 LASER Pattern list...

Page 14: ...irrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause gre...

Page 15: ......

Page 16: ......

Reviews: