background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/24

LED FLOWER, BEAM SWEEPER, BARREL

DESCRIPTION:

1. Optical lens
2. Hanging bracket with 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting

hook.

3. Mains cable
4. Fuse holder
5.

LED Beam Sweeper:

additional scan mirror

LED Barrel:

additional barrel shaped reflector

LED Flower:

not available

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

OPERATING INSTRUCTIONS

Once connected to the mains the device starts running.

Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.

Do not switch the unit on and off in short time intervals

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/24

LED FLOWER, BEAM SWEEPER, BARREL

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons

suffering from epilepsy.

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:

AC 230V, 50Hz

Fuse:

250V 2A slow blow (20mm glass)

Sound Control:

Internal microphone

Lamp:

46 power LEDs (R=16 + G=15 + B=15)

LED Flower:
Size:

26 x 23 x 21cm

Weight:

1.6kg

LED Beam Sweeper:
Size:

43 x 23 x 21cm

Weight:

2kg

LED Barrel:
Size:

43 x 23 x 21cm

Weight:

2.2kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Summary of Contents for LED Flower

Page 1: ...cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de i...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...ol means indoor use only This symbol means Read instructions CAUTION ENGLISH OPERATION MANUAL JB SYSTEMS 2 24 LED FLOWER BEAM SWEEPER BARREL This symbol determines the minimum distance from lighted ob...

Page 4: ...short time intervals Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing In the event of serious operating problems stop using the fixture and...

Page 5: ...ance doit tre de plus de 0 5 m tre Afin de prot ger l environnement merci de recycler les emballages autant que possible Afin d viter tout risque d incendie ou de d charge lectrique ne pas exposer cet...

Page 6: ...une p riode prolong e ou avant de changer une ampoule ou d effectuer des op rations de maintenance En cas de probl mes de fonctionnement s rieux arr tez toute utilisation de l appareil et contactez v...

Page 7: ...derdeel Dit symbool betekent het apparaat mag enkel binnenhuis worden gebruikt Dit symbool betekent Lees de handleiding Dit symbool bepaalt de minimumafstand van te belichten voorwerpen De minimumafst...

Page 8: ...ekker uit het stopcontact als het apparaat langere tijd geen dienst doet of alvorens een lamp te vervangen of alvorens een onderhoudsbeurt te beginnen Stop in geval van serieuze bedieningsproblemen me...

Page 9: ...Bedienungs und Wartungshinweise in den Dokumenten hin die dem Ger t beiliegen CAUTION DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 14 24 LED FLOWER BEAM SWEEPER BARREL Dieses Symbol bedeutet Nur innerhalb v...

Page 10: ...umgehend mit ihrem H ndler in Verbindung setzen WichtigerHinweis Nicht direkt in die Lichtquelle blicken Ger t nicht verwenden wenn sich Personen im Raum befinden die unter Epilepsie leiden WARTUNG U...

Page 11: ...e s mbolo significa uso para el interior solamente Este s mbolo significa Lea las instrucciones Este s mbolo se determina la distancia m nima de objetos iluminado La distancia m nima entre el proyecto...

Page 12: ...hufe la unidad cuando no la use por un periodo de tiempo largo o antes de cambiar la bombilla o comenzar una reparaci n En el caso de problemas serios de manejo deje de usar la instalaci n y contacte...

Page 13: ...WER BEAM SWEEPER BARREL Este s mbolo significa utiliza o unicamente em espa os fechados Este s mbolo significa Leia instru es Este s mbolo determina a dist ncia m nima dos objetos iluminados A dist nc...

Page 14: ...dade em curtos per odos de tempo Desligue sempre a unidade da corrente quando n o a utilizar durante longos per odos de tempo antes de substituir a l mpada ou de efectuar a manuten o Caso a unidade ap...

Reviews: