background image

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

3/22 

INFERNO 

LAMP (RE)PLACEMENT 

In case of replacement of the lamp or maintenance, do not open the fixture within 
10 minutes until the unit cools down after switching off. Always unplug the unit 
before servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When 
replacing parts, please only genuine spare parts. 

  Unplug the mains cable.  

 Wait for about 10 minutes until the unit has been cooled 

down. 

  Unscrew the screws that close the lamp compartment of the 

fixture and open it.  

  On the inside you will see the lamp socket. Tear the lamp 

socket gently out of the lamp compartment. 

  Unplug the old lamp. Hold the lamp socket while unplugging 

the lamp instead of pulling the cable! 

  Hold the lamp socket while pressing the new lamp gently in 

the socket.

 

 

Attention! 

Check the label on the backside of the device or 

see the technical specifications in this manual to know which 
lamp should be used. Never install lamps with a higher 
wattage! Lamps with higher wattage generate temperatures 
the device was not designed for. If the device uses a lamp 
transformer, it will burn due to current overload. 

  Don’t touch the bulb inside the reflector of the lamp with bare 

hands! This drastically shortens the lifespan of the lamp. If you touched the lamp, clean it with a cloth 
and a little denatured alcohol. Wipe the lamp off before installing. 

  Put the new lamp back inside the unit. Be sure that the wires don’t touch the lamp. 

  Close the lamp compartment.  

 Done! 

 

OVERHEAD RIGGING 

Best installation distance: 

A projection distance of +/- 5 meters from the wall is perfect. From 
this distance the projection will cover an area of 3.1 m x 3.1 m.  
 

 

Important:

 

The installation must be carried out by qualified 

service personal only. Improper installation can result in 
serious injuries and/or damage to property.  Overhead rigging 
requires extensive experience! Working load limits should be 
respected, certified installation materials should be used, the 
installed device should be inspected regularly for safety.

 

  Make sure the area below the installation place is free from unwanted persons during rigging, de-

rigging and servicing. 

  Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The 

fixture must be fixed 

at least 50cm

 from surrounding walls. 

  The device should be installed out of reach of people and outside areas where persons may walk by or 

be seated. 

 Before rigging make sure that the installation area can hold a minimum point load of 10times the 

device’s weight. 

  Always use a certified safety cable that can hold 12times the weight of the device when installing the 

unit. This secondary safety attachment should be installed in a way that no part of the installation can 
drop more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

  Don’t cover any ventilation openings as this may result in overheating.  

  The operator has to make sure that the safety-relating and machine-technical installations are approved 

by an expert before using them for the first time. The installations should be inspected every year by a 
skilled person to be sure that safety is still optimal. 

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

4/22 

INFERNO 

OPERATING INSTRUCTIONS 

  Once connected to the mains the device starts running. 

  Regular breaks during operation are essential to maximize the life of this device as it is not designed for 

continual use. 

  Do not switch the unit on and off in short time intervals as this reduces the lamp life. 

  The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare-hands during 

its operation. 

 Always unplug the unit when it is not used for a longer time or before replacing the bulb or start 

servicing. 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

 

Important: 

Never look directly into the light source! Don’t use the effect in the presence of persons 

suffering from epilepsy. 

 

MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All screws used for installing the device and any of its parts should be tightly fastened and may not be 

corroded. 

  Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The mains cables must be in impeccable condition and should be replaced immediately when even a 

small problem is detected. 

  In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 
damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s 
optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

  Clean the external optics at least once every 30 days.  

  Clean the internal optics at least every 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

Mains Input: 

AC 230V, 50Hz  

Fuse: 

250V 5A slow blow (20mm glass) 

Lamp:

 

ELC 250W / 24V 

Size:

 

36 x 23 x 13cm  

Weight:

 7.0kg 

 

Every information is subject to change without prior notice

Summary of Contents for INFERNO

Page 1: ...5 by BEGLEC cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung...

Page 2: ...rials and or liquids The fixture must be fixed at least 50cm from surrounding walls Don t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean t...

Page 3: ...0cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating...

Page 4: ...source d alimentation Placez l appareil dans un endroit bien ventil loign de tout mat riau ou liquide inflammable L appareil doit tre fix 50cm minimum des murs Ne pas couvrir les ouvertures de ventil...

Page 5: ...fi uniquement Une installation incorrecte peut causer des blessures s v res et ou endommager l appareil L installation en hauteur exige de l exp rience Les limites de charge doivent tre respect es du...

Page 6: ...onale voorschriften Het is vastgesteld dat het apparaat er zich aan houdt en de desbetreffende verklaringen en documenten zijn door de fabrikant afgegeven Het toestel is ontworpen om decoratieve licht...

Page 7: ...verpakking als het toestel vervoerd moet worden Om veiligheidsredenen is het verboden om ongeautoriseerde modificaties aan het toestel aan te brengen Belangrijk Kijk nooit rechtstreeks in de lichtbro...

Page 8: ...De oppervlaktetemperatuur van het apparaat kan 85 bereiken Raak gedurende het bedienen van het apparaat de behuizing niet met blote handen aan Trekt U altijd de stekker uit het stopcontact als het app...

Page 9: ...sigkeiten ins Innere des Ger ts gelangen lassen Kurzschlu oder Fehlfunktion k nnen die Folge sein Falls es doch einmal vorkommen sollte bitte sofort Netzstecker ziehen und vom Stromkreis trennen Ger t...

Page 10: ...eischwingende Aufh ngung ist gef hrlich und sollte auf gar keinen Fall in Betracht gezogen werden Ventilations ffnungen nicht abdecken da berhitzungsgefahr DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 18 22...

Page 11: ...material inflamable y o l quidos La instalaci n debe ser fijada al menos a 50 cm de distancia de los muros circundantes No cubra ninguna apertura de ventilaci n ya que esto podr a resultar en sobrecal...

Page 12: ...eva con libertad es peligroso y no debe considerarse ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 22 22 INFERNO No cubra ninguna apertura de ventilaci n ya que esto podr a resultar en sobrecalentamiento...

Reviews: