background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/28

GOBO FLOWER

LAMP (RE)PLACEMENT

In case of replacement of the lamp or maintenance, do not open the fixture within 10
minutes until the unit cools down after switching off. Always unplug the unit before
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When replacing

parts, please only genuine spare parts.

Unplug the mains cable.

Wait for about 10 minutes until the unit has been cooled down.

Unscrew the screw that closes the lamp compartment of the
fixture and open de top of the enclosure.

On the inside you will see the lamp socket. Tear the lamp socket
gently out of the lamp compartment.

Unplug the old lamp. Hold the lamp socket while unplugging the
lamp instead of pulling the cable!

Hold the lamp socket while pressing the new lamp gently in the
socket.

Attention!

Check the label on the backside of the device or see

the technical specifications in this manual to know which lamp
should be used. Never install lamps with a higher wattage!
Lamps with higher wattage generate temperatures the device
was not designed for. If the device uses a lamp transformer, it
will burn due to current overload.

Don’t touch the bulb inside the reflector of the lamp with bare hands! This drastically shortens the lifespan
of the lamp. If you touched the lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off
before installing.

Put the new lamp back inside the unit. Be sure that the wires don’t touch the lamp.

Close the lamp compartment.

Done!

OVERHEAD RIGGING

Best installation distance:

A projection distance of +/- 5 meters from the wall is perfect. From this distance the projection will cover an
area of 3.3 m x 3.3 m.

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/28

GOBO FLOWER

OPERATING INSTRUCTIONS

Once connected to the mains the device starts running.

Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.

Do not switch the unit on and off in short time intervals as this reduces the lamp life.

The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare-hands during its
operation.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

Important:

Never look directly into the light source! Don’t use the effect in the presence of persons

suffering from epilepsy.

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:

AC 230V, 50Hz

Fuse:

250V 5A slow blow (20mm glass)

Sound Control:

Internal microphone

Lamp:

ELC 250W / 24V

Size:

31 x 27 x 14cm

Weight:

8.2kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Summary of Contents for Gobo Flower

Page 1: ... cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones Manual do utilizador EN FR NL DU ES PT ...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Page 3: ...o adapt to the surrounding temperatures when bringing it into a warm room after transport Condense sometimes prevents the unit from working at full performance or may even cause damages This unit is for indoor use only Don t place metal objects or spill liquid inside the unit Electric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power Locate ...

Page 4: ...d be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure that safety is ...

Page 5: ...nement merci de recycler les emballages autant que possible Un nouvel effet lumière peut provoquer de la fumée et ou une odeur non souhaitée disparaissant après quelques minutes Afin d éviter tout risque d incendie ou de choc électrique ne pas exposer cet appareil à la pluie ou l humidité Pour éviter la formation de condensation à l intérieur de l appareil patientez quelques minutes pour laisser l...

Page 6: ...e l installer FRANÇAIS MODE D EMPLOI JB SYSTEMS 8 28 GOBO FLOWER Insérez la nouvelle ampoule à l intérieur de l unité Assurez vous que les fils ne touchent pas l ampoule Refermez le compartiment à ampoules Voilà INSTALLATION EN HAUTEUR Installation préférée Vous obtenez le meilleur effet quand le projecteur est placé à environ 5m du mur A cette distance l effet couvrira une surface de 3 3m x 3 3m ...

Page 7: ...une de ces informations peut être modifiée sans avertissement préalable Vous pouvez télécharger la dernière version de ce mode d emploi de notre site Web www beglec com NEDERLANDS HANDLEIDING JB SYSTEMS 10 28 GOBO FLOWER Hartelijk dank voor de aankoop van dit JB Systems product Om ten volle te kunnen profiteren van alle mogelijkheden en voor uw eigen veiligheid gelieve de aanwijzingen zeer zorgvul...

Page 8: ...nde staat te zijn Zet het apparaat onmiddellijk af als de elektrische kabel gekneusd of beschadigd is De kabel moet vervangen worden door de fabrikant zelf zijn dealer of vergelijkbare bekwame personen om een brand te voorkomen Laat de elektrische draad nooit in contact komen met andere draden Volgens de veiligheidsvoorschriften moet deze installatie geaard worden Sluit het apparaat niet aan op ee...

Page 9: ...ienen van het apparaat de behuizing niet met blote handen aan Trekt U altijd de stekker uit het stopcontact als het apparaat langere tijd geen dienst doet of alvorens een lamp te vervangen of alvorens een onderhoudsbeurt te beginnen Stop in geval van serieuze bedieningsproblemen met het gebruiken van het apparaat en stel U onmiddellijk in verbinding met uw dealer Belangrijk Kijk nooit rechtstreeks...

Page 10: ...d legt sich nach einigen Minuten Zur Vermeidung von Stromschlag oder Feuer Gerät bitte nicht Regen oder Feuchtigkeit aussetzen Zur Vermeidung von Kondensation im Inneren des Geräts bitte nach Transport in eine warme Umgebung einige Zeit zum Temperaturausgleich bringen Kondensation kann zu Leistungsverlust des Gerätes oder gar Beschädigung führen Gerät nicht im Freien und in feuchten Räumen und Umg...

Page 11: ...n Betracht gezogen werden Ventilationsöffnungen nicht abdecken da Überhitzungsgefahr Betreiber muß sicherstellen dass die sicherheitsrelevanten und technischen Installationen vor Erstbetrieb fachmännisch vorgenommen worden sind Installationen sollten jährlich durch qualifiziertes Fachpersonal inspiziert werden um jederzeit einen sicheren Betrieb zu gewährleisten DEUTSCH BEDIENUNGSANLEITUNG JB SYST...

Page 12: ...ara evitar que se forme condensación en el interior permita que la unidad se adapte a las temperaturas circundantes cuando la lleve a una habitación cálida después de transporte Condensación algunas veces impide que la unidad funcione a rendimiento pleno o puede incluso causar daños Esta unidad es sólo para uso interior No coloque objetos metálicos o derrame líquidos dentro de la unidad Podría res...

Page 13: ...abo sólo por personal cualificado Una instalación impropia podría resultar en serias heridas y o daño a la propiedad El aparejado superior requiere una larga experiencia Los límites de las cargas de trabajo deben respetarse materiales certificados de instalación deben ser usados el aparato instalado debería ser inspeccionado regularmente por seguridad Asegúrese de que el área por debajo del sitio ...

Page 14: ...ADOR JB SYSTEMS 24 28 GOBO FLOWER Obrigado por ter adquirido este produto da JB Systems De modo a tirar total proveito das possibilidades deste produto por favor leia este manual com atenção CARACTERÍSTICAS Esta unidade está protegida contra interferências rádio Este produto cumpre as exigências impostas pelas presentes directivas nacionais e europeias A conformidade deste produto foi comprovada e...

Page 15: ...a reguladores de intensidade Utilize sempre um cabo de segurança aprovado ao instalar a unidade De forma a não correr risco de choque eléctrico não abra a cobertura da unidade À excepção da lâmpada e do fusível não existem peças que possam ser substituídas pelo utilizador Nunca repare um fusível nem tente operar a unidade sem fusível Substitua sempre um fusível danificado por outro com as mesmas c...

Page 16: ...dade pode alcançar os 85ºC Não toque na cobertura da unidade com mãos descobertas durante o funcionamento Desligue sempre a unidade da corrente quando não a utilizar durante longos períodos de tempo antes de substituir a lâmpada ou de efectuar a manutenção Caso a unidade apresente problemas sérios de funcionamento interrompa a utilização da unidade e contacte o seu revendedor imediatamente Importa...

Reviews: