DESCRIPTION:

1. Handle
2. Mains switch
3. Electronic dimmer
4. Automatic thermal fuse
5. Mains input cable
6. Lamp compartment
7. Mounting b 2 knobs
8. Color changer
9. Focus + zoom adjuster
10. Diaphragm (iris) + gobo holder

LAMP (RE)PLACEMENT

In case of replacement of the lamp or maintenance, do not open the fixture within 10
minutes until the unit cools down after switching off. Always unplug the unit before
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When
replacing parts, please use only genuine spare parts.

Switch off the unit and unplug the mains cable.

Wait for about 10 minutes until the unit has been cooled down.

Use a screwdriver to unscrew the 3 screws (marked “A”) that close the
lamp compartment of the fixture.

Tear the lamp socket gently out of the lamp compartment.

Unplug the old lamp. Hold the lamp socket while unplugging the lamp
instead of pulling the cable!

Hold the lamp socket while pressing the new lamp gently in the socket.

Attention!

Check the label on the backside of the device or see the

technical specifications in this manual to know which lamp should be
used. Never install lamps with a higher wattage! Lamps with higher
wattage generate temperatures the device was not designed for. If the device uses a lamp transformer, it
will burn due to current overload.

Don’t touch the bulb with bare hands! This drastically shortens the lifespan of the lamp. If you touched the
lamp, clean it with a cloth and a little denatured alcohol. Wipe the lamp off before installing.

Put the new lamp back inside the unit. Be sure that the wires don’t touch the lamp.

Close the lamp compartment with the screws.

For maximum light output it’s important that the lamp is well centered inside the reflector. To do this ,
switch the device on and adjust the lamp until the light output is maximal. Check the drawing to see which
are the 3 adjusting points (marked “B”) to do this.

Done!

OVERHEAD RIGGING / INSTALLING ON LIGHT STAND

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/31

FOLLOW SPOT 1000W

extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

OVERHEAD RIGGING:

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 100cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

INSTALLING ON LIGHTING STAND:

Make sure the area is free from unwanted persons at all times.

Locate the device in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 100cm

from surrounding walls.

Make sure to install the device on a very stable light stand using the mounting bracket. The hole in the
mounting bracket has a diameter of 13mm.

Adjust the desired inclination-angle of the device and fasten both knobs very tightly.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

OPERATING INSTRUCTIONS

Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.

Do not switch the unit on and off in short time intervals as this reduces the lamp life.

The units’ surface temperature may reach up to 160°C. Don’t touch the housing with bare-hands during its
operation.

Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.

In the event of serious operating problems, stop using the fixture and contact your dealer immediately.

Important:

Never look directly into the light source!

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

Summary of Contents for FSP-1000

Page 1: ...or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones Manu...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...ment please try to recycle the packing material as much as possible A new light effect sometimes causes some unwanted smoke and or smell This is normal and disappears after some minutes To prevent fir...

Page 4: ...ight Always use a certified safety cable that can hold 12times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the insta...

Page 5: ...y the parts carefully Clean the external optics at least once every 30 days Clean the internal optics at least every 90 days Attention We strongly recommend internal cleaning to be carried out by qual...

Page 6: ...s exposer cet appareil la pluie ou l humidit Pour viter la formation de condensation l int rieur de l appareil patientez quelques minutes pour laisser l appareil s adapter la temp rature ambiante lors...

Page 7: ...ou la maintenance Placez l appareil dans un endroit bien ventil loign de tout mat riau ou liquide inflammable L appareil doit tre fix 100cm minimum des murs l entour L appareil doit tre hors de port...

Page 8: ...t product voldoet aan de gangbare Europese en nationale voorschriften Het is vastgesteld dat het apparaat er zich aan houdt en de desbetreffende verklaringen en documenten zijn door de fabrikant afgeg...

Page 9: ...van het toestel Om elektrische schokken te voorkomen moet U de behuizing niet openen Afgezien van de lamp en de zekering zitten er geen onderdelen in die door de gebruiker moeten worden onderhouden R...

Page 10: ...en de installaties worden gekeurd door een vakman om te controleren of de veiligheid nog steeds perfect is BEDIENINGSVOORSCHRIFTEN Regelmatige pauzes bij het bedienen zijn noodzakelijk om het apparaat...

Page 11: ...EDIENUNGSANLEITUNG JB SYSTEMS 18 31 FOLLOW SPOT 1000W Dieses Symbol stellt fest der minimale Abstand von beleuchteten Gegenst nden Der minimale Abstand zwischen Projektor und dem belichteten Gegenstan...

Page 12: ...ations ffnungen nicht abdecken da berhitzungsgefahr Betreiber mu sicherstellen dass die sicherheitsrelevanten und technischen Installationen vor Erstbetrieb fachm nnisch vorgenommen worden sind Instal...

Page 13: ...flujo luminoso alto 3600lux 5m 1080lux 9m Protecci n contra sobrecarga y enfriamiento de ventilador forzado Toma l mpara G22 ANTES DEL USO Antes de utilizar esta unidad por favor compruebe que no hay...

Page 14: ...de reducci n de luz Siempre use un cable de seguridad apropiado y certificado cuando instale la unidad Para prevenir descargas el ctricas no abra la tapa Aparte de la l mpara y fusibles principales no...

Page 15: ...adas cada a o por una persona con conocimientos para asegurar que la seguridad es todav a ptima INSTRUCCIONES DE USO Descansos regulares durante su uso son esenciales para maximizar la vida de este ap...

Page 16: ...evitar risco de fogo ou choque el ctrico n o exponha este produto a chuva ou humidade De forma a evitar a forma o de condensa o no interior da unidade ao transport la para ambiente quente aguarde alg...

Page 17: ...ircundantes A unidade deve ser instalada fora do alcance das pessoas afastada de reas onde as pessoas possam passar ou sentar se Antes de proceder instala o certifique se que a rea seleccionada pode s...

Page 18: ...mpar o interior da unidade uma vez por ano De forma a optimizar a projec o de luz limpe as lentes pticas internas e externas e ou espelhos periodicamente A regularidade das limpezas depende do ambient...

Reviews: