background image

ENGLISH 

 

OPERATION MANUAL 

 

JB SYSTEMS

®

 

2/8 

CAM-SPOT 50TW

 

SAFETY INSTRUCTIONS: 

  To protect the environment, please try to recycle the packing material as much as possible. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding  temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign 
object enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture 

must be fixed at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

  Maximum safe ambient temperature is 40

°C. Don’t use this unit at higher ambient temperatures. 

  Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and 

servicing. 

  Allow the device about 10 minutes to cool down before to start servicing. 

  Always unplug the unit when it is not used for a longer time or before to start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the unit. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged. It must be replaced  by the  manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed in order to comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In  order  to  prevent  electric  shock,  do  not  open  the  cover.  Apart  from  the  mains  fuse  there  are  no  user 

serviceable parts inside. 

 

Never

 repair a fuse or bypass the fuse holder. 

Always

 replace a damaged fuse with a fuse of the same type 

and electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

Important: 

Never look directly into the light source! Don’t use the effect in the presence of persons suffering 

from epilepsy. 

 

CAUTION:

 To reduce the risk of electric shock, do not remove 

the top cover. No user-serviceable parts inside. Refer servicing 
to qualified service personnel only. 

 

The lightning flash with arrowhead symbol within the equilateral triangle is intended to  alert the 
use or the presence of un-

insulated “dangerous voltage” within the product’s enclosure that may 

be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of important operation and  maintenance (servicing) instructions in the literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This  symbol  determines:  the  minimum  distance  from  lighted  objects.  The  minimum  distance 
between light-output and the illuminated surface must be more than 1 meters

 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

Summary of Contents for CAM-SPOT 50TW

Page 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 CAM SPOT 50TW ...

Page 2: ......

Page 3: ...d as a table stand Completely silent operation no noisy cooling fans on board PowerCon compatible powerinlet BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device left our factory in perfect condition and well packaged It is absolutely necessary for the user to stric...

Page 4: ...ged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to prevent electri...

Page 5: ... decrease the selected value 9 ENTER BUTTON used to confirm your actions 10 COLOR TEMP change the color temperature from warm white WW 3000K to cold white CW 6000K 11 USB SOCKET Please note that this USB connector is NOT used for updates or to connect the unit to a PC Instead this USB connector makes it very easy to add wireless DMX to the unit Just add the optional WTR DMX DONGLE from BRITEQ and ...

Page 6: ...ver any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure that safety is still optimal SETUP MENU HOW TO SETUP With the setup menu you can fully configure the pr...

Page 7: ...the last selected static color will be used to set the value Once you have the desired level press the ENTER button to save it DMX Fail Used to set the desired DMX loss setting Press the MENU button or UP DOWN buttons until the desired function is showing on the display Hold Projector keeps the last valid output before DMX loss Manual Projector goes to manual mode when DMX is lost Black Out Projec...

Page 8: ... setup the master All slaves must be set to SLAVE mode IMPORTANT make sure that no DMX controller is connected this will result in unexpected behavior Electrical installation for two or more units in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units Pin layout XLR 3pin Pin1 GND...

Page 9: ... 1 1 1 CW 000 255 2 2 2 WW 000 255 1 Linear CCT 000 255 2 3 3 Dimmer 000 255 4 Strobe 000 255 MAINTENANCE Make sure the area below the installation place is free from unwanted persons during servicing Switch off the unit unplug the mains cable and wait until the unit has been cooled down During inspection the following points should be checked All screws used for installing the device and any of i...

Page 10: ...d the relevant statements and documents have been deposited by the manufacturer Mains Input AC 180 240V 50Hz Power consumption 52 Watt Power connections PowerCon DMX connections 3pin XLR male female Lamp LED 50W COB CW WW CRI 90 Beam Angle 22 IP Rating IP20 Size see drawing Weight 2 7 kg The information might be modified without prior notice You can download the latest version of this user manual ...

Page 11: ......

Page 12: ......

Reviews: