background image

ENGLISH 

USER MANUAL 

 

 

JB SYSTEMS® 

2/12 

USB PARTYSET 

 

SAFETY INSTRUCTIONS: 

CAUTION:

 To reduce the risk of electric shock, do not remove the top cover. 

No  user-serviceable  parts  inside.  Refer  servicing  to  qualified  service 
personnel only. 

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use 
or  the  presence  of  un-

insulated “dangerous  voltage”  within  the product’s enclosure that may be of 

sufficient magnitude to constitute a risk of electric shock. 
The exclamation point within the equilateral triangle is intended to alert the user to the presence of 
important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying  this 
appliance. 

  

  This symbol means: indoor use only. 

  

  This symbol means: Read instructions. 

  

 

This symbol determines: the minimum distance from lighted objects. The minimum distance between 
light-output and the illuminated surface must be more than 1 meter. 

  To protect the environment, please try to recycle the packing material as much as possible. 

  A new light effect sometimes causes some unwanted smoke and/or smell. This is normal and disappears 

after some minutes. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign 
object enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture 

must be fixed at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

  The save ambient temperature is between 15° & 

40°C. Don’t use this unit at higher ambient temperatures. 

  Make  sure  the  area  below  the  installation  place  is  free  from  unwanted  persons  during  rigging, de-rigging 

and servicing. 

  Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the rear panel of the unit. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged. It must be replaced  by the  manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed to in order comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In order to prevent electric shock, do not open the cover. Apart from the lamp and mains fuse there are no 

user serviceable parts inside. 

 

Never

 repair a fuse  or bypass the fuse holder. 

Always

 replace a damaged fuse  with a fuse of the same 

type and electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

CAUTION

Summary of Contents for B06215

Page 1: ......

Page 2: ......

Page 3: ...a 4 7 10 or 34 channels Standalone sound activated internal microphone or automatic IR remote infrared remote control Prepared for wireless DMX just plug in an optional WTR DMX DONGLE Briteq order code 4645 Several bars can be connected in master slave to create wonderful synchronized shows 3 digit LED display for easy menu navigation BEFORE USE Before you start using this unit please check if the...

Page 4: ...cm from surrounding walls Don t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate this device The save ambient temperature is between 15 40 C Don t use this unit at higher ambient temperatures Make sure the area below the installation place is free...

Page 5: ...jectors from our USB range can be powered and controlled via these extra USB connectors JB Systems USB LASER USB MUSHROOM USB DERBY USB PAR 8 CONTROL PANEL Used to select the different functions of the bar see further to learn how to operate the unit 9 DISPLAY shows all the necessary information about settings and working modes 10 INTERNAL MICROPHONE The built in microphone is used to synchronize ...

Page 6: ...se the UP and DOWN buttons to select the desired program speed from S 01 slow to S 99 fast Press ENTER to confirm your setting Use the UP and DOWN buttons to select the desired motor speed from M 00 STOP to M 99 fastest only needed if you use effects with a rotation motor Press ENTER to confirm your setting You can connect several USB PARTYSETs together just put the first unit of the chain in one ...

Page 7: ...strobe effect o S 00 no output o S 01 to S 99 slow strobe to fast strobe o S 99 full on and NO strobe effect o S 100 Sound controlled strobe Press the ENTER button to confirm your choice IMPORTANT if you have set a correct color and the strobe is set to a value between S 01 and S 100 but you have no light output go back to the 2 SOUND CONTROLLED STANDALONE MODE settings in the menu see above and c...

Page 8: ...you press this button you will activate another sound program SP01 SP02 PROGRAM SPEED press number 0 to 9 to select the desired speed for the automatic programs not sound controlled 0 slowest 9 fastest The other buttons are not used 6 CONTROLLED VIA DMX The USB PARTYSET can be controlled by any standard DMX controller in 4 different DMX modes 4 CHANNEL MODE for easy control over the automatic and ...

Page 9: ...ables this simply won t work Each effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode 4 CHANNEL DMX CONFIGURATION DMX Channel DMX value function remarks 1 000 009 Blackout 010 029 AM01 Mixed Automatic Shows 030 059 AM02 060 089 AM03 090 129 AP01 AP18 Automatic Program 01 18 use Channel 2 128 159 SM01 Mixed Sound Shows 160 18...

Page 10: ...matic Shows 030 059 AM02 060 089 AM03 090 129 AP01 AP18 Automatic Program 01 18 use Channel 2 128 159 SM01 Mixed Sound Shows 160 189 SM02 190 209 SM03 210 249 SP01 SP18 Sound Program 01 18 use Channel 2 250 255 Manual Mode Channel 5 to 10 are available 2 000 013 AP01 SP01 Select select a specific program Channel 1 between 090 and 129 Auto mode Ch 1 between 210 and 255 Sound Mode 014 027 AP02 SP02 ...

Page 11: ...030 059 AM02 060 089 AM03 090 129 AP01 AP18 Automatic Program 01 18 use Channel 2 128 159 SM01 Mixed Sound Shows 160 189 SM02 190 209 SM03 210 255 SP01 SP18 Sound Program 01 18 use Channel 2 2 000 013 AP01 SP01 Select select a specific program Channel 1 between 090 and 129 Auto mode Ch 1 between 210 and 255 Sound Mode 014 027 AP02 SP02 028 041 AP03 SP03 042 055 AP04 SP04 056 069 AP05 SP05 070 083 ...

Page 12: ...6 000 Stop Motor Rotation slow to fast 001 127 Clockwise rotation 128 Stop 129 255 Anticlockwise rotation Channel for projector effect 3 17 000 255 Red 0 100 18 000 255 Green 19 000 255 Blue 20 000 255 White 21 000 015 No Strobe Slow to Fast 016 255 Strobe Speed 22 000 Stop Motor Rotation slow to fast 001 127 Clockwise rotation 128 Stop 129 255 Anticlockwise rotation Channel for projector effect 4...

Page 13: ...er Press the ENTER button to enter the option settings Use the UP DOWN button to select the desired mode ON function activated The wireless IR remote controller can be used OFF function deactivated The wireless IR remote controller can NOT be used Press the ENTER button to confirm your setting o SouN When the bar is used in a sound controlled mode you can decide here how the bar should react when ...

Page 14: ... particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts carefully Clean the external optics at least once every 30 days Clean the internal optics at least every 90 days Attention We strongly recommend internal cleaning to be carried out by qualified personnel SPECIFICATIONS This u...

Page 15: ......

Page 16: ......

Reviews: