3.1 Powering the fixture
3.2 Rigging the fixture
The JBLED A7 can either be placed on the floor or hung on a trussing system in a vertical
or horizontal way. When placing the unit on the floor make sure that it stands on rigid
ground, because the air inlets in the base must not be covered with anything!
To mount the unit on a trussing system use two of the original JB-lighting omega brackets
with Camloc-connectors. The Camlocs must snap in to be locked propperly. Always attach
a safety cable to secure the unit. There is an optional omega bracket available for single
clamp attachment. This bracket must be used for horizontal not for vertical installation!
WARNING: Keep fixtures at least 0,5 m away from inflamable articles!
Always use a safety cable attached to the base!
!
Install a 3-prong grounding type plug that fits your supply.
Connected load: voltage 100-240 V, frequency 47-63 Hz
WARNING: To ensure propper installation of the plug consult
a qualified technician!
!
3. Installation
21
omega bracket
camloc connector
224
140
140
Safety cable
attachment point
brown black live
“L”
blue white neutral
“N”
yellow/green green ground
EU Model: US Model: