page 11
www.jayline.co.nz
JUNE 2018
Recognising errors and taking measures against faults
WARNINGS
Below is a list of warnings to ensure effi cient and safe operation of your UL200 wood fi re:
•
WARNING:
DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF
THIS APPLIANCE WHEN IT IS OPERATING.
•
WARNING:
DO NOT STORE FUEL OR COMBUSTABLES WITHIN APPLIANCE INSTALLATION
CLEARANCES.
•
WARNING:
NEVER OPEN THE LOWER DOOR WHEN IN USE.
•
WARNING:
DO NOT TOUCH ANY PART OF THE FIRE OTHER THAN THE DOOR HANDLE
WHEN IN USE, AS ALL PARTS ARE EXTREMELY HOT.
•
WARNING:
SUPERVISE CHILDREN AT ALL TIMES WHEN NEAR THE FIRE.
•
WARNING:
DO NOT ATTEMPT ANY CLEANING OF THE FIRE WHEN IN USE. WAIT FOR THE
APPLIANCE TO COOL DOWN BEFORE CLEANING
•
WARNING:
DO NOT REMOVE ASH FROM THE FIRE WHEN IN USE.
•
CAUTION:
THIS APPLIANCE SHOULD NOT BE OPERATED WITH CRACKED GLASS.
•
CAUTION:
DO NOT USE THE FIRE IF THERE IS A MALFUNCTION, A SUSPICION OF
BREAKAGE OR UNUSUAL NOISES.
•
CAUTION:
NEVER THROW WATER ON THE FIRE WHEN IN USE, OR USE WATER TO
EXTINGUISH THE FIRE UNDER NORMAL CONDITIONS.
•
CAUTION:
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS.
•
CAUTION:
THE USE OF PRESERVATIVE-TREATED WOOD, COAL, PLASTICS, DRIFTWOOD
AND/OR WASTE PRODUCTS AS A FUEL CAN BE HAZARDOUS.
ERROR
POSSIBLE CAUSE
MEASURE
Smell/stench in the room
Leaking seals
Check the sealing of the doors
and replace seals if necessary
Smell/stench in the room
Flue too short/poor draught
Check the fl ue system is not
blocked and is clean. Have the
fi re maintenance & cleaning
procedures been done?
The fl ame in the upper
combustion chamber
continously goes out
Flue too short/poor draught
Excess moisture in fuel
Check the fl ue system is not
blocked and is clean. Have the
fi re maintenance & cleaning
procedures been done?
Change fuel for moisture level
10-25% only.