SECTION 8
PLUMBING SYSTEM
47
W
ATER
P
RESSURE
R
EGULATOR
(C
USTOMER
S
UPPLIED
)
Excessive pressure from water supply
systems may be encountered in some parks,
especially in mountain regions. Water
pressure regulators are available to protect
the RV water system against such high
pressure. Water pressure regulators
(customer supplied) are available from your
RV dealer to protect the RV plumbing system
against such high pressure.
12-V
OLT
W
ATER
P
UMP
&
S
WITCH
When you want to use water in your RV and
the RV is not hooked up to city water, you will
need sufficient 12-volt DC power to run the
water pump. Depending on your model, the
pump will be located under the bed, in a
cupboard, under the RV or under the sink.
The switch to operate the water pump is
located on the command center panel.
Once activated, the
water pump (also
known as the
demand pump) will
self-prime, and
provide water. The
water pump
continues to run until
approximately 45 lbs.
of pressure is
achieved then shut off. The water pump will
automatically re-start when pressure drops.
Some cycling may occur, depending on the
volume of water being released. The water
pump has a built-in check valve to prevent
water from back flowing.
The water pump switch should be in the
OFF position when the RV is unattended
for any amount of time. If something would
happen to the water system, this may help
limit water damage to a smaller area.
For more information
Read the OEM operator’s manual.
W
ATER
H
EATER
The water heater is designed to heat water
quickly and efficiently. The water heater OEM
has preset the sensing limit to maintain the
water temperature when the water heater is
activated. If you have not used the water
heater for two weeks or more it may result in
hydrogen gas in the water lines. To reduce
the risk of injury under these conditions, open
the hot water faucet for several minutes at the
kitchen sink before you use any electrical
appliance connected to the hot water system.
If hydrogen is present, you probably will hear
an unusual sound such as air escaping
through the pipe as the water begins to flow.
Hydrogen gas may be present even after
water has been drained from the tank. Open
faucet at the sink and allow the water system
to vent for five to ten minutes (or as needed).
Do not replace any component part with an
accessory part that is not authorized by the
water heater OEM (i.e., an “add-on”
electric heating element, etc.). Such items
are not approved to be installed, could
create an unsafe condition and will void all
warranties.
Not using a water pressure regulator when
using city water may cause the o-rings to
blow. To prevent damage to the plumbing
system or components when using the city
water connection, a 45 lb. (315 KPa) rated
water pressure regulator is recommended.
HYDROGEN GAS IS EXTREMELY
FLAMMABLE.
Do not smoke or have any
open flame near the open faucet. On DSI
water heater models make sure the interior
control switch is OFF during the above
listed procedure.
Fig 8.3 Water pump
Summary of Contents for Recon ZX 2008
Page 1: ...www jayco com Sport Utility Fifth Wheel Owner s Manual Model Year 2008...
Page 12: ...SECTION 1 WARRANTY SERVICE 8...
Page 13: ...SECTION 1 WARRANTY SERVICE 9...
Page 14: ...SECTION 1 WARRANTY SERVICE 10...
Page 28: ...SECTION 3 PRE TRAVEL INFORMATION 24 THIS PAGE IS INTENTIONALLY BLANK...
Page 38: ...SECTION 5 RV TIRES 34 THIS PAGE IS INTENTIONALLY BLANK...
Page 48: ...SECTION 7 FUEL SYSTEM 44 THIS PAGE IS INTENTIONALLY BLANK...
Page 68: ...SECTION 9 PROPANE SYSTEM 64 THIS PAGE IS INTENTIONALLY BLANK...
Page 72: ...SECTION 10 SLIDEOUT SYSTEMS 68 THIS PAGE IS INTENTIONALLY BLANK...
Page 86: ...SECTION 11 CAMPING OPERATING 82 THIS PAGE IS INTENTIONALLY BLANK...
Page 104: ...SECTION 13 SPECIFICATIONS GLOSSARY 100 THIS PAGE IS INTENTIONALLY BLANK...
Page 105: ...SECTION 14 ADDENDUM S 101 There are no addendums issued at this time...
Page 106: ...SECTION 14 ADDENDUM S 102 THIS PAGE IS INTENTIONALLY BLANK...