65
Section 5: Slideout Systems
Park brake LED flashing
-Parking brake not set
(if applicable)
-Ground signal lost at
park brake control
-Set parking brake (if ap-
plicable)
-Check for continuity to
ground on wire plugged
into park brake connector at
control box.
Low voltage LED flashing
Incoming violated to
control box is below
12.0 VDC
Check 2-pin power connec-
tor at control box. If voltage
is below 12.0 VDC contact
O.E.M for power and ground
supplies.
Preventative Maintenance
The Power Gear® slideout system requires very little maintenance. Read and follow these
procedures:
When the room is extended, visually inspect the slide rail assemblies. Check for
excess buildup of dirt or foreign material; remove any debris that may be present.
If the system squeaks or makes any noises, blow out any debris from the gear rack
arms and apply a dry lubricant to prevent and/or stop squeaking.
Refer to the Power Gear® website
Override Modes
In the event of component failure or loss of system power, your slideout can be manually
overridden and retracted for travel.
NOTE: During the override procedure, the unit will exit this mode if the
room has not been moved for two (2) minutes or if a fault is detected dur-
ing room movement. The Fault Code (RED) and Room or Lock Movement
(GREEN) LEDs will flash rapidly for 10 seconds to indicate the override pro-
cedure failed. After 10 seconds of flashing, the control will automatically de-
fault to FAULT CODE 1. Programming must be restarted.
NOTE After overriding the system, the room control will need to be re-pro-
grammed by an OEM authorized dealer.
Emergency Retract Mode
Use this procedure when there is
NO
loss of power or electrical problem with the system.
1.
Remove the touchpad (Fig 4) from the wall.
2.
Prior to clearing the MAJOR fault, record the number of
RED & GREEN flashes observed on the touchpad (Fig 6).
This information will help your dealer/service center in
troubleshooting the slideout system.
3.
Press and hold the SET STOPS/CLEAR FAULTS button
on the back of the touchpad for five (5) seconds (Fig 2). Both RED & GREEN LEDs
will be on solid while pressing this button. After 5 seconds, the GREEN LED will
begin flashing and the RED LED will remain solid on.
4.
The unit is now ready to retract the room. Press and hold the ROOM SLIDEOUT MO-
TOR buttons 1 and 2 on the back of the touchpad (Fig 3).
Table of Contents
Summary of Contents for NORTH POINT 2023
Page 2: ......
Page 6: ...F Table of Contents ...
Page 8: ...2 Section 1 Warranty Service Table of Contents ...
Page 22: ...16 Section 1 Warranty Service Notes Table of Contents ...
Page 38: ...32 Section 3 Pre Travel Information Notes Table of Contents ...
Page 60: ...54 Section 4 Vehicle Operation Notes Table of Contents ...
Page 96: ...90 Section 6 Electrical System Notes Table of Contents ...
Page 106: ...100 Section 7 Fuel Propane System Notes Table of Contents ...
Page 140: ...134 Section 8 Plumbing System Notes Table of Contents ...
Page 152: ...146 Section 10 Appliances Notes Table of Contents ...
Page 156: ...150 Section 11 Electronics Notes Table of Contents ...
Page 166: ...160 Section 12 Interior Notes Table of Contents ...
Page 172: ...166 Section 13 Exterior Fifth Wheels Sealant Diagram Table of Contents ...
Page 176: ...170 Section 14 Travel Camping Storage Checklists Notes Table of Contents ...
Page 181: ...175 Section 15 Additional Information Notes Table of Contents ...