Section 5: Slideout Systems
79
8.
Release the OUT button when the room is fully extended or the IN button when fully
retracted, and stops moving.
9.
Turn
OFF
the on/off switch or key.
Fault Diagnostics / Troubleshooting
The control has the ability to detect and display several faults. When a fault is detected,
room movement stops and two different LEDs will flash in a pattern.
The RED FAULT CODE LED (Fig 4) will flash a number of times corresponding to a spe
-
cific fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will flash GREEN a number of times cor
-
responding to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
MAJOR and MINOR faults
; faults must be cleared for the room to operate normally.
MINOR
faults can be cleared by pushing and releasing the
IN
or
OUT
buttons on
the wall touchpad (Fig 4).
MAJOR
faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).
Fault
Code
Fault
Type
Fault Codes
Description
Possible Cause
Possible Solution
1
Major
Stops not
programmed
-Stops have not been
set
-Stops were cleared
-Stops were improperly
set
Steps need to be programmed
by an authorized service
facility.
2
Minor
System Fault
-Obstruction present
-Excessive system drag
Run room in opposite direc-
tion. If it continues to move
in the opposite direction,
remove obstruction, exces-
sive weight in room or repair
of damaged component. If
room stops moving in op-
posite direction, observe fault
code and refer to this chart
4
Major
Excessive
Battery Volt-
age
-Bad or loose connec-
tion
-Defective harness
-Open or shorted motor
-Check all connections at
control box and motor
-Check the harness for bro-
ken wires.
-Put 12.0 VDC direct to the
motor. If it does not run,
replace the motor.
NOTE:
For MAJOR faults, the control must be overridden by
following the EMERGENCY RETRACT MODE in the OVERRIDE
MODES section.
Summary of Contents for JAY FEATHER Towables 2020
Page 1: ...Owner s Manual 0195624 2020 2020 Towables...
Page 2: ......
Page 4: ......
Page 12: ...10...
Page 20: ...Section 1 Warranty Service 18...
Page 27: ...Section 1 Warranty Service 25...
Page 28: ...Section 1 Warranty Service 26...
Page 46: ...Section 3 Pre Travel Information 44 Notes...
Page 70: ...Section 4 Vehicle Operation 68 Notes...
Page 114: ...Section 7 Fuel Propane System 112 Notes...
Page 150: ...Section 11 Electronics 148 Notes...
Page 172: ...Section 14 Travel Camping Storage Checklists 170 Notes...