OPD Overfill Protection
Supplied with your parktrailer is information that applies to the Type 1 ACME LP Gas Connection
on your LP gas tank(s). Please read all information contained in the supplied literature.
The following instructions will supply information for correct tank/valve orientation, regulator
placement, hose length, hose routing and tankcover placement. Make sure these steps are followed
for proper LP connections.
DUAL TANK ASSEMBLY WITH TANK RACK ON A-FRAME OR FRONT TRUNK
1. Connect the 3/8" low-pressure hose to the outlet of the
two-stage regulator.
2. Place the tanks on the bracket provided on the A-frame
and secure them so the outlet of the tankvalves point
outward from the front of the parktrailer.
3. Using the threaded center rod, position the regulator
bracket. This centers the regulator between the two tanks
as they are secured to the base tray.
4. Attach the inverted flare x 11" Type-1 pigtail hose to the
regulator inlet and the right hand swivel nut to the tank
valve.
I
WARNING: The pigtail hose must be installed to
avoid tension or pulling stress at either end of the hose.
I
WARNING: Keep the pigtail hose away from sharp edges of the tank collar, rigid
corners, walls, doors or other compartment structures including the cover.
NOTE: The regulator is typically installed with the inlet fittings at the same level as the tank
outlet valves. Due to bracket design, wing nut clearance or cover restrictions, the
regulator fittings may not be in perfect alignment with the tankvalves. A variance
of two (2) inches (5 cm) above or below the line will permit the hoses to be properly
installed.
28
Cove Owner’s Manual
Fig. 4-18