Where appropriate, if the battery has been removed for charging, replace it and reconnect the 

cables. 

Protection 

a)

 

Reverse Polarity

If the alligator clamps are connected improperly to the battery terminals, the reverse polarity 

LED will indicate the reversed polarity; warning buzzer will also sound and “E1” illuminates on

LED main display. When this occurs simply disconnect the battery charger from the AC power 

and connect the alligator clamps correctly to the battery terminals. Reconnect the charger to 

the AC power. 

b)

 

Over-Heat 

If internal temperature of the unit is too high, warning buzzer will sound and “E3” illuminates

on LED main display. When this occurs simply disconnect from AC power mains and battery. 

Let the unit cool down before charging again. 

c)

 

Over-Current 

If output current is too high, warning buzzer will sound and “E4’ illuminates on LED main

display. When this occurs, please disconnect the unit from AC power mains and battery. 

Try to re-set and recharge. Or set to lower output. 

d)

 

Short-Circuited 

If “+” and “-” alligator clamps are shorted or voltage of battery is below 3V, warning buzzer 

will sound and “

[3.0

” illuminates on LED main display. When this occurs, please disconnect

from AC power mains and check the polarity connection. If polarity connection is correct, 

please check the battery. 

e)

 

Voltage of battery >28V 

If voltage of battery is over 28V, warning buzzer will sound and “

]28

” illuminates on LED

main display. When this occurs, please disconnect from AC power mains and battery. Don’t try

to recharge that battery. 

f)

 

Detection Failure 

If type (voltage) of battery is failed to be detected or the type of battery is not suitable to be

recharged by MB-3623, warning buzzer will sound and “

E2

” illuminates on LED main display.

When this occurs, please check the type of battery. For example, if the battery is lithium or for

electric car, do not charge with MB-3623. If type of battery is applicable for MB-3623, please 

try to re-set and recharge. If situation persists, battery may be faulty. 

It is essential to keep your battery regularly charged throughout the year, especially during 

the winter months. In the winter the effectiveness of your car battery is reduced by the cold. 

Oil is thick. Engines are difficult to start as the heater, windscreen wipers and lights are all 

draining power. It is at this time that batteries have to be at peak power. If your battery is not 

regularly maintained and kept fully charged, it can cause problems and a possible breakdown. 

Listed are some helpful hints on how to keep your battery healthy in conjunction with your

Battery Charger. 

Faulty Cells 

Batteries are usually made with six cells. One of these cells can deteriorate or get damaged. If,

after several hours charging your battery is still flat, you should test the battery. Take 

hydrometer readings from each cell in the battery. If one reading is lower than the others, this 

could indicate a faulty cell. 

MAINTENANCE AND CARE

Summary of Contents for MB3623

Page 1: ...DIGITAL SMART 6 12 24V 15A DC AUTO DETECTION BATTERY CHARGER Suitable for Regular Wet Flooded Sealed Maintenance Free Lead Acid Gel SLA and Deep Cycle Batteries between 20 200Ah...

Page 2: ...es This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision...

Page 3: ...Battery 14 2V 12V Battery 28 4V 24V Battery for Wet Flooded Lead Acid MF battery selection 7V 6V Battery 14 0V 12V Battery 28V 24V Battery for Gel SLA battery selection 7 2V 6V Battery 14 4V 12V Batte...

Page 4: ...V 2A 2A 2 7A 2 7A 0 5 1A 10 Minute max 9 Hour max 36 Hour max 24V Battery Voltage 10 14 4V Gel Cell SLA 14 0V Regular 14 2V Deep Cycle 14 4V 13 61V at 25 Auto 8 10V Detect 2 7 15A Current Amperes 2 7...

Page 5: ...reset the memory function NOTE The memory function consumes power from battery and may run it flat Temperature Compensation A sensor will automatically adjust the charging voltage if the temperature d...

Page 6: ...AD CAREFULLY BEFORE USING Suitable for 6 12 24V Wet Flooded Lead Acid Maintenance Free MF Gel SLA and Deep cycle Batteries between 20 200Ah 1 Charging your battery It is essential to disconnect the ba...

Page 7: ...one of the following Gel Cell SLA Select for charging all type of Gel Cell SLA batteries Regular Select for charging all types of lead acid batteries SEALED MF or WET FLOODED TYPE Deep Select for cha...

Page 8: ...ard settings at Charging Rate 2Amp DC Battery Type Gel Cell SLA 2 Auto Detection function is for detecting the type voltage of battery 3 During auto detection process around 10minutes unit does not re...

Page 9: ...charging voltage you want Remark For 6V Battery only 2A shows up on LED main display and this indicates only 2Amp is available For 12V Battery 2A 7A 15A illuminates in each press and this indicates 2A...

Page 10: ...warning buzzer will sound and 28 illuminates on LED main display When this occurs please disconnect from AC power mains and battery Don t try to recharge that battery f Detection Failure If type volt...

Page 11: ...hat cell Put the fluid back into the cell after testing taking care not to splash the fluid about Trouble often can be corrected by the user Please read this chart for possible solutions to common pro...

Page 12: ...DC for 6 12 24V battery 7A DC for 12 24V battery 15A DC for 12V battery Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your...

Reviews: