124610 Rev.
B
3
E N G L I S H
I NS TA LL A TIO N
NOTICE:
Please reference the JAY Fusion Cushion Owner’s
Manual for set-up and adjustment of the cushion. The
following instructions pertain to the installation and
adjustmen
t of the Air Insert only.
A.
INSTALLATION OF THE INFLATION TUBE(S)
Some configurations of the JAY Fusion Cushion with the
Air
Insert
come with the inflation tube(s) un-installed. If this is the
case, you will have received the following
parts:
A second tube will be included
if the air insert was a dual
chamber insert. A coupling
connector (A) will have already
been installed in the truncated
inflation tubes.
•
Figure 1 shows a Dual chambered
Air Insert
ready to have
the tube length attached by following the steps below.
To install the inflation tube(s)
1. Install the
Air Insert
into the JAY Fusion foam
base with inner cover as
outlined in the instruc-
tions below.
2. Measure the length of
inflation tube required
for your specific cushion
size (Figure 2). Do this by threading the tube through the
loops on the inner cover to the front edge. Measure about
1/2” (13mm) from the front edge of the cushion, and run it
the distance (L) until the open end matches up with the tube
valve coming out of the Insert.
3. Cut the length of inflation tube as measured using a sharp
pair of scissors.
4. Insert the coupling connector into the cut length of each infla-
tion tube,
6. Insert the valve
through the slot in
the outer cover
behind the JAY
Fusion logo. The
valve is intended to
protrude through
the slot and be
secured by the side
band on the JAY
Fusion cover. (Figure 6)
CUT
CUT
13mm
13mm
L
L
6
2.
With the
Air Insert
installed, the
inflation tube(s) need to
be secured to the inner cover.
Your
Air Insert may have one
or two
inflation tubes
depend
ing if it is a
single
chamber insert
or a
dual chamber
insert.
Use the fabric
loops on
either side of
the inner
cover to
route the
inflation
tube(s).
(Figures 4 and 5)
3.
Thread the inflation tube through the loops starting at the
rear of the inner cover and inserting the tube through
each
loop, working your
way around to the
front of the product.
4.
If the
Air Insert is dual
chambered, do
the
same for the sec
ond
inflation tube on
the opposite side.
5.
Re-install the outer cover by sliding it over the base and
inner cover assembly. It is best to hold the inflation valve
in
place with your hand as you slide the cover over the
assem-bly.
1. Air Insert.
2.
1 or 2 lengths of tube with one end terminated by an infla-
tion valve, the other end
1
open.
2
A
B.
I
NSTALLATION OF THE AIR INSERT INTO CUSHION
1.
With the outer cover removed from the JAY Fusion
foam
base, install the
Air Insert
into the
Well. Ensure
that the
Air Insert
is aligned with the well
and that the
inflation tubes
are to the rear
of the
cushion. (See
Figure 3).
Ensure the
Velcro
attached to the
Air
Insert is aligned with
the
matching Velcro
adhered to the inner
cover.