E N G L I S H

C L EAN IN G  A ND   MA INT ENA NC E

A

.

CLEANING AND DISINFECTING YOUR AIR INSERT

Cleaning and disinfecting are two separate processes. Cleaning

 

must precede disinfection.

     CLEANING THE 

AIR INSERT

To clean the 

Air Insert

, gently pull it

 

out of the recess in the foam 

base, taking care to gently pull the

 

valve through the foam. Deflate 

the cushion, close the valve(s) and

 

place in a large sink. Gently 

scrub the air cells and the spaces

 

between them with a soft plastic 

bristle brush, sponge or wash-cloth. Liquid dishwashing or laundry 
detergent or other general-purpose cleaning product is suggested. 
For institutional cleaning, a

 

general housekeeping disinfectant 

cleaner may be used.

     DISINFECTING THE 

AIR INSERT

To disinfect the 

Air Insert

, use a germi-cidal product that meets 

infection control needs.  A disinfectant

 

with tuberculocidal 

properties is recommended. Follow the manu-facturer’s dilution 
directions. For home disinfection, use solutions

 

of approximately 

1/2 cup liquid household bleach per quart of

 

water (125 ml bleach 

to 1 liter of water). Keep the clean cushion

 

wet with bleach 

solution for 10 minutes. Rinse thoroughly and

 

dry.

WARNING

Disinfectants are not effective on porous surfaces, such as
foam, if the cushion becomes soiled or contaminated. DO
NOT use with multiple users.

CAUTION– DO NOT USE OIL-BASED LOTIONS OR LANOLIN ON

YOUR CUSHION AS THEY MAY COMPROMISE THE
INTEGRITY OF THE NEOPRENE RUBBER.

B. REPAIRS

Each JAY Fusion Cushion with a 

Air Insert

 is shipped complete 

with a repair kit and instructions for

 

minor repairs. The 

following information can be used if repair

 

instructions have 

been lost or misplaced.

IF A LEAK OCCURS:

1. Place your cushion cells down and over-inflate until all four

corners touch.

2. Immerse the over-inflated cushion in water to locate the

leak.

3. Once the leak has been located, mark the leak by inserting a

toothpick into the hole.

4. Allow the cushion to dry thoroughly.
5. Remove the toothpick, and clean the area around the hole

with the alcohol wipe provided. Let the surface dry.

6. Peel the backing from the patch provided,  and centering the

patch, place it over the hole.

7. Press the patch down firmly until a good seal is achieved.
8. The cushion is now ready for use. Adjust the cushion for

proper inflation following the instructions in this manual.

Although patches do not change the performance of the cushion,
they should be monitored periodically to ensure effectiveness in
addressing the leak. If the patch is not successful in addressing the
problem, or if more extensive damage is present, please contact
your supplier immediately. 

Replacing Valves

1. Firmly grip the rubber valve stem and remove the old infla-

tion valve by using pliers.

CAUTION– DO NOT REMOVE AN INFLATION VALVE BY HOLDING

THE CUSHION AND PULLING THE VALVE, DOING SO
MAY TEAR THE CUSHION.

2. Moisten the ribbed end of the replacement valve and insert it

into the valve stem until the rubber is snug to the body of
the valve.