AAA-055-00138
Rev. 1/14/15
Jaylor Owner Manual
- 33 -
Mini Mixer Models
14.0
CONTROLS
14.1 Weighing (All Models)
The scale system on all models includes four weigh-bars. The weigh-bars electronically measure
the amount of ration inside the mixing chamber.
When attaching the indicator to the machine, be sure that it is securely fastened.
On A50 and A100 models, the scale indicator is located on the upper mixer drum (near operator).
The mounting bracket arm assembly allows the scale indicator to be turned to face every
direction. Be sure not to pinch the wire.
NOTE - Tighten swivel joint lock nut to the point where there is enough friction to hold the
indicator in position but it can still easily be turned by hand.
Figure 27 - A50 and A100 Scale Mounting Bracket Arm Adjustment
1. Swivel Joint -
Used to adjust the direction of the scale indicator face.
2. Scale indicator
– Displays the weight of ration in the drum.
NOTE - The scale will be programmed to display weight in either kilograms (kg) or pounds
(lbs.). This is set by the manufacturer and must be ordered to suit. If your scale is not
programmed to your preferred units of measurement, or for any other settings, please see
your “Mini Weighing System User Handbook” which has been provided by the scale
system manufacturer.