Doc ref. :
332190D –
EN
28.04.2014
Page 11 / 49
4.6 Testing the unit
• Step 1
Place the handle on the charger.
The green indicator light on the charger comes on. If not, check that the handle is paired with the
charger. Refer to the section « Setting the charger into service ».
• Step 2
Press the reset button to engage the output relays of the receiver, K1-K2
The 2 indicator lights K1 and K2 should come on and indicator light V2 of the receiver should go
off.
• Step 3
Pick up the enabling handle and place the trigger in the « active » position within 10 seconds.
The antenna symbol should appear on the display screen.
Notes
:
1 - Safety relays K1 and K2 deenergise when the trigger is released or clenched (in the case of 3-
position trigger).
2 - Safety relays K1 and K2 energise again when the trigger is reactivated after it has gone through
the « released » position
(1)
3 – The safety relays remain active when the trigger is released within 30 cm of the charger.
(1)
Wait 3 or 4 seconds before you reactivate the trigger to allow the receiver to correctly reinitialise.
Button
B4
Button
B2
Button
B3
Button
B1
Display
(1) released
(2) activated
(3) clenched
3-position trigger
(1) released
(2) activated
2-position trigger