Gb
Fr
324501E
revision02
- 69 -
De
5-
Press simultaneously on both transmitter buttons controlling relays that must be
interlocked.
-
V2
and
V3
LEDs blink alternatively, then go off.
The receiver recorded the interlocking of two relays.
6-
Repeat point n°5 if other interlocking must be realized.
7-
Once the programming procedure is finished, switch off the receiver and remove
jumper
JP1
(ORRS on ORRA) , or set the
JP1
microswitch to the "OFF"
position (ORRD).
5.6.1- Particularity of the «bistable ON/OFF» relay operating mode
In the «
bistable
» relay operating mode, the conflicting commands are not
necessarily simultaneously emitted, in that case a priority is given to the last pressed
button.
Example:
interlocking between the button no.1 and the button no.2 in «bistable»
relay operating mode.
An impulse on the button no.1 activates the relay no.1 (and remains activated), an
impulse on the button no.2 deactivates the relay no.1 and activates the relay no.2.
5.6.2- Particularity of ORRA industrial receiver, «large model»
The interlocking functions are distributed among 4 relay groups :
Group 1 : relay nb.1 (R1) to relay nb.4 (R4),
Group 2 : relay nb.5 (R5) to relay nb.8 (R8),
Group 3 : relay nb.9 (R9) to relay nb.12 (R12),
Group 4 : relay nb.13 (R13) to relay nb.16 (R16).
)
)
)
)
)
The interlocking functions can only be programmed for this receiver
on relays belonging to a
same group
.
Example :
interlocking is possible between relay R1 and relay R3 but not possible
between relays R1 and R6.
Summary of Contents for OREi21SL1
Page 2: ... 2 324501E revision02 ...
Page 123: ...Gb De 324501E revision02 123 Fr Annexes Appendix Anhang ...
Page 134: ... 134 324501E revision02 ...
Page 136: ... 136 324501E revision02 ...
Page 137: ...324501E revision02 137 NOTES ...
Page 138: ... 138 324501E revision02 NOTES ...
Page 139: ...324501E revision02 139 ...