www.javad.com
Maxor User’s Manual
2-15
C O N F I G U R A T I O N
MinPad Configuration
5.
Click on
File->Disconnect
, then
File->Exit
to quit PCView.
Notice:
Disconnecting the receiver from the computer before
exiting will eliminate any possible conflict in the
management of your serial ports.
Once the receiver is configured, the configuration will remain until you change
it either using PCView or clearing the NVRAM.
MinPad Configuration
The Maxor's minimum interface (MinPad) consists of three keys (Power, FN,
and Reset) and up to four LEDs (STAT, REC, BATT, and RX) that control and
display the receiver's operation (Figure 2-18).
Figure 2-18. Maxor MinPad
The MinPad performs numerous functions:
• Turn the receiver on/off, put it in Sleep or Zero power mode.
• Turn data recording on or off (FN key).
• Change the receiver's information mode.
• Show the number of GPS (green) and GLONASS (orange) satellites being
tracked (STAT LED).
• Show data recording status (REC LED).
• Show each time data records to internal memory (REC LED).