Figure 6. WiFi client configuration tab
Access to Serial port via Network: In the
Communication/Advanced tab it is necessary
to select Serial port as Console (see figure be-
low) and reboot deice from Administration/
Management or do power cycle. After reboot
the device is ready for connection to serial
port CLI interface with user name “jlink”
password “jLTEXXXXX” where “XXXXX” is
serial number of device which is written in
device label. For connecting to HPT404BT JL
serial port needed to setup with following pa-
rameters:
• Baudrate 115200
• Parity none
• Data Bits 8
• Stop Bits 1
• Handshake hardware
Figure 7. Advanced configuration tab
Access to Serial port via Network: In the
Communication/Advanced tab it is necessary
to select Serial port as Network (see figure
below) and reboot device from Administra-
tion/Management or do power cycle.
After reboot device is ready for telnet con-
nection to serial port using “Ser2Net” as log-
in and “jlinklte” as password. For connecting
to HPT404BT JL serial port needed to setup
with following parameters:
• Baudrate 115200
• Parity none
• Data Bits 8
• Stop Bits 1
• Handshake hardware
Figure 8. Advanced configuration tab
9
HPT404BT JL USER MANUAL