IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS.

This manual contains information and instructions for proper operation and maintenance of your therapy bath. Failure to follow these 

instructions could result in personal injury, electrical shock, or fire.

WARNING: When using this unit, basic precautions should always be followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

DANGER:  TO REDUCE THE RISK OF INJURY FOLLOW THESE PRECAUTIONS:

A.  DANGER: 

To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.

B.  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
C.  The water in a therapy bath should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are  

   considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a shower to cool down.  

  Longer exposures may result in hyperthermia. 
D.  Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body tempera 

  ture of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, leth 

  argy, drowsiness, and fainting. The effects of hyperthermia include:

 

a) Failure to perceive heat;

 

b) Failure to recognize the need to exit the hydromassage bathtub;

 

c) Unawareness of impending hazard;

 

d) Fetal damage in pregnant women;

 

e) Physical inability to exit the hydromassage bathtub; and

 

f) Unconsciousness resulting in the danger of drowning.

WARNING – The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia

E.   The use of drugs or alcoholic beverages before or during therapy bath use may lead to unconsciousness with the possibility of  

    drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants, antihistamines, vasoconstric 

    tors, vasodilators, hypnotics, narcotics, or tranquilizers.

F.   Lower water temperatures are recommended for extended use (exceeding 10 -15 minutes) and for young children.
G.  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy,    

  pregnant or possibly pregnant women should limit therapy bath water temperatures to 100°F (38°C).
H.  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should  

  consult a physician before using a therapy bath.
I.    Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness  

    while other medication may affect heart rate, blood pressure, and circulation.

DANGER: 

To reduce the risk of injury, enter and exit the bath slowly.

 Do not operate this unit unless the suction cover is 

attached over the suction inlet fitting and the jet assemblies are installed. There should be at least two (2) inches of water above the 

highest jet location during therapy bath operation. 

NEVER RUN UNIT DRY.

WARNING:

 Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed electrician 

and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TEST

 button. The GFCI should interrupt the pow-

er.
Push the 

RESET

 button and the power should be restored. If the GFCI fails to operate in this manner, there is the possibility of an elec-

tric shock. 

DO NOT USE

. Disconnect the unit and have the problem corrected by a qualified service technician.

To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 40°C 

(104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do not use oil base additives 

in your therapy bath.

CAUTION: 

Do not use harsh abrasives or solvents for cleaning this unit.

INSTALLER/OWNER BEARS ALL RESPONSIBILITY TO COMPLY WITH ALL STATE AND

LOCAL CODES WHEN INSTALLING THIS PRODUCT

SAVE THESE INSTRUCTIONS

Summary of Contents for KT525 SR

Page 1: ...romptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason Hydrotherapy is not responsible for dama...

Page 2: ...2021 Jason Hydrotherapy 501 771 4477 Page 2 of 28 Customer Service 800 255 5766 NOTES...

Page 3: ...timulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children...

Page 4: ...es et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent...

Page 5: ...cant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loi gn s de toutes sources de chaleur moduites par le abin ATTENTION Garder les cheveu...

Page 6: ...Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty period co...

Page 7: ...ature sensors and Jason s Bluetooth Sound Immersion system WHIRLPOOL FEATURES Jason s Whirlpool hydrotherapy bath utilizes Perfect Pressure Perfect Flow jets that are directed at key muscle groups all...

Page 8: ...ONS cont STANDARD EDITION ELECTRONIC CONTROLS ICONS POWER Icon WHIRLPOOL Icon WP MW AW AIRMASSEUR Icon AM MA AW MICROSILK Icon MS MW MA LED Icon Optional PILLOW Icon Optional WP MW AW Blower SPEED Ico...

Page 9: ...een all the colors A single press of the icon will progress the light to the next mode or color Press and hold the icon to cycle through the FADE mode release the icon to choose any custom color Order...

Page 10: ...solid GREEN This purge cycle can be canceled by pressing and holding the power button for five 5 seconds Starting the AirMasseur will turn OFF any other therapy equipment running at that time MicroSi...

Page 11: ...t in timer shuts off the therapy equipment twenty 20 minutes after being activated Customized User Settings Menu The Signature Edition system offers many features that can be customized through the Se...

Page 12: ...the six 6 buttons will begin to light Press the illuminated button to proceed to the next icon The LED light will be tested next Select the check mark to verify the appropriate Red Green or Blue color...

Page 13: ...can be canceled by selecting the CANCEL button Starting the AirMasseur will turn OFF any other therapy equipment running at that time The PILLOW icon is used to activate the neck jets when the Jetted...

Page 14: ...h thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No 2 available at...

Page 15: ...aining To verify use a level on top of the deck on both ends and front of the bath Jason baths are designed to be support ed at the base of the bath If the floor is smooth and level the bath s Level F...

Page 16: ...the area of intended installa tion cut the equipment support strap s to allow the equip ment to rest firmly level with the bottom of the bath on the floor We recommend securing the equipment mounts t...

Page 17: ...air inlet of the bath Choose a loca tion as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the piping exact remote mount location and service...

Page 18: ...and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma terials and does not require a bonding conductor Grounding is required...

Page 19: ...ICL 297 Female Nema Load Connections Not Used Ozone Male Nema Line Connection Keypad IDU 264 LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 WP Pump Male Nema Line Connection To Dedicated 120...

Page 20: ...Bluetooth Sound Immersion Included on Signature Edition AIRMASSEUR AM SYSTEM Notes Asinglededicated120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require...

Page 21: ...372 WP Pump To Dedicated 120V 60Hz 20A GFCI Protected Service LWL Temp Sensor ITW 209 1 2 Male Nema Line Connection Blower Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service...

Page 22: ...ted120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require multi ple outlets be installed on the single service Optional Thermo Comfort Surface Heater Heat...

Page 23: ...L Temp Sensor ITW 209 1 2 Male Nema Line Connection Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service Heater MS Pump TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Option...

Page 24: ...Male Nema Line Connection Light ASW Display ICL Light Water Detect Power LED Config Switch Load 2 Load 1 LEDs ICL 297 Female Nema Load Connections Ozone Male Nema Line Connection Keypad IDU 264 LED C...

Page 25: ...2021 Jason Hydrotherapy 501 771 4477 Page 25 of 28 Customer Service 800 255 5766 NOTES...

Page 26: ...ers and GFCI if tripped Check fuses and replace if bad Check voltage at motor when control is on If no voltage control is defective b Make sure plug is fully inserted into the control box outlet c Che...

Page 27: ...er recently using the bathtub and its equipment b Purge cycle has started with no apparent warning a No action is needed This is a normal feature to help keep the air channel dry and sanitary b Follow...

Page 28: ...e free from defects in workmanship and materials as provided in the enclosed Warranty Statement and Warranty validation card The pre addressed warranty registration card MUST be filled out by the purc...