background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 8 of 9

  

 

 

             

Customer Service :  800.255.5766 

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 9 of 9

  

 

 

             

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

IMPORTANT SAFETY INSTRUCTIONS

INStRuCtIONS PERtaININg tO thE RISk Of fIRE, ElECtRIC ShOCk, OR INJuRY tO PER-

SONS.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to follow these 
instructions could result in personal injury, electrical shock, or fire.

WaRNINg: When using this unit, basic precautions should always be followed, including the following:

REaD aND fOllOW all INStRuCtIONS CaREfullY

DaNgER:

 

tO REDuCE thE RISk Of INJuRY fOllOW thESE PRECautIONS: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

b.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufac-

turer.

C.

  The water in a  therapy bath should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are 

considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a shower to cool down. 
Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, dizziness and fainting, and it can be 
fatal. Lower water temperatures are recommended for extended use (exceeding 10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 38°C (100°F).

E.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility  of  drowning.  Never  use  the  therapy  bath  while  under  the  influence  of  alcohol,  anticoagulants,  stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

f.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should 

consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness 

while other medication may affect heart rate, blood pressure, and circulation.

DaNgER:

 

 

to reduce the risk of injury, enter and exit the bath slowly. 

Do not operate this unit unless the suction cover is attached over 

the suction inlet fitting and the jet assemblies are installed.  There should be at least two (2) inches of water above the highest jet 
location during therapy bath operation.

 NEVER RuN uNIt DRY.

WaRNINg:

 

Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed electrician 
and should be tested on a regular basis (at least monthly). To test the GFCI push the 

tESt

 button. The GFCI should interrupt the 

power. Push the 

RESEt

 button and the power should be restored. If the GFCI fails to operate in this manner, there is the possibility 

of an electric shock. 

DO NOt uSE. 

Disconnect the unit and have the problem corrected by a qualified service technician. 

To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 
40°C (104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do not use oil base 
additives in your therapy bath.

CautION: 

Do not use harsh abrasives or solvents for cleaning this unit.

INStallER/OWNER bEaRS all RESPONSIbIlItY tO COmPlY WIth all StatE  

aND lOCal CODES WhEN INStallINg thIS PRODuCt.

SaVE thESE INStRuCtIONS

 

Jason InternatIonal, Inc.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Summary of Contents for Integrity A6060

Page 1: ...factory are the buyer s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting...

Page 2: ...x 91 x 52 148 91 x 43 cm 217 72 x 36 x 20 5 45 36 x 17 in 44 8 183 x 91 x 52 170 91 x 43 cm 219 72 x 36 x 20 5 45 46 1 183 x 91 x 52 170 225 60 x 42 x 20 5 44 36 x 17 in 45 4 152 x 107 x 52 167 91 x...

Page 3: ...ant backer board and the deck of the bath NOTE If you use a tile flange kit modify the framing to support the bath lip as shown in Figure 1 A minimum ventilation opening of 2 x 4 5 x 10 cm for 3 the b...

Page 4: ...lve and the elbow by removing the two 2 screws in the elbow Omit this step on baths where the blower is not factory installed and remote mounting is required Installtheblowerintheremotelocation Therem...

Page 5: ...althofMassachusetts installation is to be done by a Massachusetts licensed plumber CLEANING Remove all loose debris 3 Construction plaster or excess grout can be removed with the use of a wood edge tr...

Page 6: ...e whether used as an AirMasseur or a soaking bath Blower TheJasonIntegrityTM AirMasseur systemcontainsavariable speed controlled heated air blower The blower provided is factory tested when assembled...

Page 7: ...ial number proof of purchase andmodelnumber Thiswillinsureaquickresponse on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of t...

Page 8: ...uch other manufacturer or supplier To obtain warranty service you must contact the retailer from which the merchandise was purchased or Company s distributor in your area Written notice of warranty de...

Page 9: ...asoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a...

Reviews: