InTrODuCTIOn

This manual contains all of the information needed for the 
proper operation of this Jason Integrity

TM

 AirMasseur

®

 bath. 

The  bath  has  been  designed  to  provide  years  of  relaxing 
trouble-free  service,  provided  the  unit  is  maintained  and 
operated in accordance with these instructions.  

WaRNINg: bEfORE OPERatINg, REfER tO thE INStRuCtIONS 

PERtaININg tO thE RISk Of fIRE, ElECtRIC ShOCk, OR INJuRY 

tO PERSONS ON thE laSt PagE Of thIS maNual.

Thoroughly clean and disinfect the unit as described in the 

ClEaNINg

 section of the 

uSER maINtENaNCE INStRuCtIONS

 

section  of  this  owner’s  manual  before  its  first  use  and 
periodically thereafter.

All Jason Integrity

TM

 AirMasseur

®

 baths are pre-plumbed at 

the factory with standard equipment.  Standard equipment 
includes a quiet 1 HP, variable-speed blower with integral 
heater; 20-minute timer ; and Air switch controls with  “On/
Off” and blower speed functions.

FIllIng  anD DraInIng

Close the drain and fill the bath with water to at least 10” 
below the bath deck. The maximum recommended bathing  
temperature is 104°F (40°C).

Before starting the blower, ensure that it is plugged into the 
air switch control box and that the control box is plugged into 
its dedicated electrical service connection.

Turn the blower Off before draining the water. The bath unit 
and its plumbing are designed to drain after each use, whether 
used as an AirMasseur

®

 or a soaking bath.. 

BlOwer

The Jason Integrity

TM

 AirMasseur

®

 system contains a variable 

speed-controlled heated air blower. The blower provided is 
factory tested when assembled onto the bath.  The blower 
must be plugged into the air switch control box, which must 
be plugged into its dedicated GFCI electrical service prior 
to turning it on.  

aIr On/OFF BuTTOn

The  Air  On/Off  button  (air  switch  activator) 
allows the user to turn the blower On and Off 
and controls the blowers intensity.  Momentarily 
depress the Air On/Off button to start or to stop 
the air blower.  A timer will automatically stop 
the air blower after 20 minutes of operation if 
it is not stopped manually.

NOtE: 

If the unit fails to operate, check the breaker panel 

to insure that the circuit breaker is On. Check the GFCI 

by testing and resetting it. If the unit still fails to operate, 

refer to the 

trouble Shooting guide

 section of this manual.

blOWER SPEED

Once the blower is On, to decrease the air output, press and 
hold the Air On/Off button until the desired intensity is reached, 
then release the Air On/Off button. To increase the air intensity, 
press and hold the Air On/Off button until the desired intensity 
is reached, then release the Air On/Off button. 

COnTrOl BOX

The blowers Air On/Off button control box is built to plug into 
the dedicated GFCI electrical circuit.  A 36” powercord with 
a plug end is prewired to the blower, which must be plugged 
into  the  control  box.    A  built-in  timer  shuts  the  blower  off 
20-minutes after being activated.  

auTOMaTIC Purge CYCle

Fifteen minutes after the blower is stopped and the bath is 
drained, the blower will automatically start for two (2) minutes 
to purge and dry the air channel system.    

Summary of Contents for Integrity A6060

Page 1: ...factory are the buyer s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting...

Page 2: ...x 91 x 52 148 91 x 43 cm 217 72 x 36 x 20 5 45 36 x 17 in 44 8 183 x 91 x 52 170 91 x 43 cm 219 72 x 36 x 20 5 45 46 1 183 x 91 x 52 170 225 60 x 42 x 20 5 44 36 x 17 in 45 4 152 x 107 x 52 167 91 x...

Page 3: ...ant backer board and the deck of the bath NOTE If you use a tile flange kit modify the framing to support the bath lip as shown in Figure 1 A minimum ventilation opening of 2 x 4 5 x 10 cm for 3 the b...

Page 4: ...lve and the elbow by removing the two 2 screws in the elbow Omit this step on baths where the blower is not factory installed and remote mounting is required Installtheblowerintheremotelocation Therem...

Page 5: ...althofMassachusetts installation is to be done by a Massachusetts licensed plumber CLEANING Remove all loose debris 3 Construction plaster or excess grout can be removed with the use of a wood edge tr...

Page 6: ...e whether used as an AirMasseur or a soaking bath Blower TheJasonIntegrityTM AirMasseur systemcontainsavariable speed controlled heated air blower The blower provided is factory tested when assembled...

Page 7: ...ial number proof of purchase andmodelnumber Thiswillinsureaquickresponse on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of t...

Page 8: ...uch other manufacturer or supplier To obtain warranty service you must contact the retailer from which the merchandise was purchased or Company s distributor in your area Written notice of warranty de...

Page 9: ...asoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a...

Reviews: