The Jason Home Spa System is the most advanced bath
manufactured by Jason International, Inc. and features the
ultimate in luxury bathing for the leisure bath industry. All
components must be properly connected for the bath to
function correctly.
The Home Spa Control Box
The pumps, blower, keypads, LED light, Ozone Sanitation
Unit and the water level / temperature sensor must be
plugged into the proper receptacles for correct operation of
the Home spa system. See
Figure 4
for connections.
(A) The power cords for the Service Connection #1 control
boxes must be connected into a 120V, 20amp, GFCI
dedicated circuit.
(B) The U1 Whirlpool pump’s power cord should be plugged
into the female cord connection on the ozone unit, prewired
to the control box.
installation instRUCtions (cont.)
Figure 4
Home SpA ConTrol box ConneCTionS
(C) Eight-pin mini-DIN terminal for the Home Spa U1
keypad.
(D) Six-pin mini-DIN terminal for LED light.
(E) Six-pin mini-DIN terminal for installation of the water
sensor to the U1 pump control box.
(F) The blower’s power cord will need to be pugged into the
center control box. Refer to the
eLeCTRICaL
section of the
manual for connnecting the blower to the control box.
(G) The power cord for the Service Connection #2 control
box must be connected into a 120V, 20amp, GFCI dedicated
circuit.
(H) The U2 Whirlpool pump’s power cord should be plugged
into the female cord on U2 pump control box.
(I) Eight-pin mini-DIN terminal for the Home Spa U2 keypad.
(J) The jetted neck pillow (JNP) solenoid cables should be
connected into the green solenoid terminal located in the
center control box.
E D
C
Ozone
IMC-213
ISD-237
Remote
[REM]
U1
Keypad
LEDs
I
IMC-213
Blower
U1
JNP
Solenoids
U2
JNP
Solenoids
U2
Keypad
Water/
Temp
Sensor
A
To Dedicated
120V / 60Hz 20A
GFCI Protected Service
CPH
Pump
U2
U1
CPH
Pump
To Dedicated
120V / 60Hz 20A
GFCI Protected Service
B
C
D
E
F
G
H
I
J