Home spa toUCHpad

All functions of the Jason Home Spa bath can be conveniently 
operated with either one of the two Home Spa digital keypad 
controls which control the operation of the two whirlpool 
pumps, the air blower, underwater mood lights, and the jetted 
neck pillows. The dual keypads are used to run individual 
pumps and jetted neck pillows. The same blower and lights 
are controlled from both keypads.

Whirlpool on/off icon

To control the operation of the whirlpool pump motor, press 
and release for each setting: On or Off. A 20 minute decreasing 
timer will be initiated when the pump motor starts. Press and 
hold the Pump icon to cycle through each pump setting. The 
Pump icon lights when the water is at operating level and the 
LCD displays “System Ready”. The LCD will display “WP Off” 
or “WP On” when the key is pressed. It also toggles between 
Temperature and Timer at 5 second intervals. “Low Water” 
is displayed for 5 seconds if no water is detected.

Jetted neck pillow icon

To control the operation of the jetted neck pillow, press and 
release for each setting, you can set for a constant flow on 
both jets, a pulsing flow on both jets, or a pulsing alternating 
flow between jets. Press and hold the Pillow icon to cycle 
through the various pillow settings. The Pillow icon will light 
whenever the pump is running. The solenoids will open for 
two (2) minutes to drain during the purge cycle countdown. 
The LCD will display “Pillow On”, “Pillow Pulse1”, “Pillow 
Pulse2”, or “Pillow Off” while the key is pressed.

Airmasseur® on/off and mode icon

To control the operation of the blower, simply press and 
release to change the setting to Constant, Wave, Pulse or 
Off. A 20 minute decreasing timer will be initiated when the 
blower motor starts. Press and hold the Blower icon to cycle 
through blower modes. The Blower icon should remain lit as 
long as the bath is connected to a power supply. The LCD 
will display “Const Air” and blower speed, “Wave Air” and 
blower speed, or “Pulse Air” and blower speed, while the 
key is pressed. The time remaining on the purge cycle is 
displayed after the bath has drained. “Purge Stop” is displayed 
while the key is pressed during the purge cycle. This action 
will terminate the purge cycle. The mode settings will be 
remembered on the next startup.

blower Speeds icon

Hold the key in Constant mode to go from High to Low then 
release and hold again to go from Low to High. Hold the 
key in Wave and Pulse mode to go from High to Medium 
and Medium to High. The system remembers the last speed 
setting on the next startup. The Blower Speeds icon will light 
up when the blower is running. The LED displays the blower 
speed from “10” (Low) or “55”(Med) to “99” (High) while the 
key is pressed. You can reduce the auto purge idle time 
from 20 minutes to 10 minutes, by pressing and holding the 
key for more than 5-seconds during the purge idle period.

leD light icon

Hold the key for less than two (2) seconds to turn the lights 
Off or On. Hold the key for more than two (2) seconds to 
change modes. The Light icon should remain lit as long as 
the bath is connected to a power supply. This function has 
a two-hour timer and remembers the last mode. The LCD 
displays “Light On” or “Light Off while the key is pressed 
for less than two (2) seconds, “Light Cycle” is displayed if 
pressed for more than two (2) seconds. 

P

AirMasseur

®

 On/Off, Mode

Blower Speeds

LED Light

IR for Remote

Whirlpool On/Off

Pillow On/Off

opeRating instRUCtions, featURes, and ContRols (cont.)

Figure 5

Summary of Contents for HSC650

Page 1: ...ge In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided by inspection or testing prior to installation If the carton shows s...

Page 2: ...ructions herein SeeUSERMAINTENANCEINSTRUCTIONSsectionofthis owner smanualforhumidityandmoldpreventionsuggestions prior to Installation 1 TheHomeSpabathisequippedwithseparatebathpumps and blower suppor...

Page 3: ...1 1 4 OVERLOAD PROTECTOR 1 5A TIME DELAY FUSE 1 4 x 1 1 4 TO MEDIA DEVICE REAR LEFT TO MEDIA DEVICE FRONT LEFT TO MEDIA DEVICE REAR RIGHT TO MEDIA DEVICE FRONT RIGHT NOTE THE NEGATIVE TERMINAL IS IDEN...

Page 4: ...g If the unit leaks with the unions hand tight then loosen the union s and check the O ring seal to ensure it is properly seated INSTALLATION INSTRUCTIONS cont 12 The acrylic surface of this bath has...

Page 5: ...w piping to the elbow of the existing piping INSTALLATION INSTRUCTIONS cont ELECTRICAL Electrical Power Supply These instructions are written assuming 60Hz 120V power supply Special notations are also...

Page 6: ...d that is temporarily secured to the packing board for shipping These boxes must remain on the control box bracket so that the two boxes can communicate properly through their infared communication fe...

Page 7: ...igure 4 Home Spa Control box connections C Eight pin mini DIN terminal for the Home Spa U1 keypad D Six pin mini DIN terminal for LED light E Six pin mini DIN terminal for installation of the water se...

Page 8: ...Refer to the Instruction Manual provided with the remote control for detailed instructions Automatic Purge Twenty 20 minutes after the control has shut off the blower will start again for a two minute...

Page 9: ...on on the Air Whirlpool bath These pumps are of efficient design incorporating high quality long life seals which provide superior service However should the pump need service suction and discharge un...

Page 10: ...r simply press and release to change the setting to Constant Wave Pulse or Off A 20 minute decreasing timer will be initiated when the blower motor starts Press and hold the Blower icon to cycle throu...

Page 11: ...mperature display from F Fahrenheit to C Celsius Product Test Diagnostics AfterselectingtheProductTestoptionfromthemenu theunit will perform a series of tests to confirm correct installation of compon...

Page 12: ...ur serial number proof of purchase and model number This will insure a quick response on warranty items The serial number can be foundonthefrontpageofthismanualoronthesmallcardadhered to the back of t...

Page 13: ...uit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a R...

Page 14: ...tion or discharge blocked a Remove obstruction b Suction air leak System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or co...

Page 15: ...of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure cir...

Page 16: ...rnational Inc 501 771 4477 Page 16 of 16 Customer Service 800 255 5766 Copyright 2014 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...