background image

Installation

5

Unpacking

Check the packaging for any signs of damage.

Carefully remove the machine and retain the packaging until 
the installation is complete.

Location

The  machine  should  be  located  in  a  suitable  position  and 
environment. Care should be taken to avoid moisture, dust, 
steam, oil or corrosive gases

Place  on  a  secure  level  surface  and  ensure  that  there  is 
adequate  clearance  around  the  machine  to  ensure  natural 
airflow.

Input connection

Before  connecting  the  machine  you  should  ensure  that  the 
correct  supply  is  available.  Details  of  the  machine 
requirements can be found on the data plate of the machine 
or in the technical parameters shown in the manual.

The equipment should be connected by a suitably qualified 
competent  person.  Always  ensure  the  equipment  has  a 
proper grounding.

Never  connect  the  machine  to  the  mains  supply  with  the 
panels removed.

Output connections 

Electrode polarity

In  general  when  using  manual  arc  welding  electrodes  the 
electrode  holder  is  connected  the  the  positive  terminal  and 
the work return to the negative terminal. Always consult the 
electrode manufacturer’s data sheet if you have any doubts.

When  using  the  machine  for  TIG  welding  the  TIG  torch 
should be connected to the negative terminal and the work 
return to the positive terminal

MMA welding

Insert  the  cable 
plug  with  electrode 
holder  into  the  “+” 
socket  on  the  front 
p a n e l  o f  t h e 
welding  machine, 
a n d  t i g h t e n  i t 
clockwise.

Insert  the  cable 
plug  of  the  work 
return  lead  into  the 
“-”ve socket on the 
front  panel  of  the 
welding  machine, 
a n d  t i g h t e n  i t 
clockwise

TIG Welding

Insert the cable plug with the work clamp into the “+” socket 

on  the  front  panel  of  the  welding  machine,  and  tighten  it 

clockwise.

I n s e r t  t h e 

cables  plug 

o f  t h e  T I G 

torch  into  the 

“-”  socket  on 

t h e  f r o n t 

panel  of  the 

machine  and 

t i g h t e n 

clockwise.

Connect  the 

gas  hose  to 

the regulator / 

fl o w m e t e r 

l o c a t e d  o n 

the shield gas 

cylinder  and 

connect  the 

other  end  to 

the machine.

8

Summary of Contents for TIG 200 Dual Voltage

Page 1: ...Operator Manual www jasic co uk TIG Series TIG 180 JT 180 TIG 180 Dual Voltage JT 180DV TIG 200 JT 200 TIG 200 Dual Voltage JT 200DV...

Page 2: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Page 3: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Page 4: ...an may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Replac...

Page 5: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Page 6: ...ow gas function Self adaptive arc force technology improves the performance of the machine when using long cable welding Excellent HF arc ignition High reliability arc striking Advanced arc ignition b...

Page 7: ...cle 35 35 35 35 35 35 No load voltage MMA V 60 60 60 60 60 60 No load voltage TIG V 65 65 65 65 65 65 Downslope time Downslope time s 0 10 0 10 0 10 0 10 0 10 0 10 Post flow time Post flow time s 0 15...

Page 8: ...e work clamp 6 output terminal To connect the TIG torch 7 Torch switch plug connection 8 Gas terminal To connect the gas hose of the TIG torch 9 2T 4T switch When the toggle switch is switched to 4T s...

Page 9: ...de polarity In general when using manual arc welding electrodes the electrode holder is connected the the positive terminal and the work return to the negative terminal Always consult the electrode ma...

Page 10: ...pens and HF arc ignition starts Keep the torch 2 4mm away from the work piece to ignite the arc When the arc is established the HF stops and current rises to the preset value Release the torch trigger...

Page 11: ...and copper Black Gas nozzle diameter mm Electrode diameter mm 6 4 0 5 8 1 0 9 5 1 6 or 2 4 11 1 3 2 Work piece thickness mm Joint form Tungsten electrode diameter mm Welding wire diameter mm Argon ga...

Page 12: ...e inside of arc welding machine Especially check for build up of dust debris on intake grills main voltage transformer inductance IGBT module the fast recover diode and PCB etc Take care when blowing...

Page 13: ...ins voltage is too low Welding can be carried out after the mains voltage recovers The no load voltage is 0 and the under voltage LED is on The mains voltage is too low Welding can be carried out afte...

Page 14: ...Electrical schematic 7 13...

Page 15: ...Parts list 8 14...

Page 16: ...137 TGI180 Dual voltage electrolytic capacitor 10 10021853 Quick socket 30 10006650 TIG180 TIG 180 Dual voltage silicon bridge 11 10043469 Front Panel 30 10037485 TIG200 Silicon bridge board 12 100420...

Page 17: ...DC TIG Series DC TIG MMA WELDING MACHINE Order code TIG180 JT 180 TIG200 JT 200 TIG180 JT 180DV TIG200 JT 200DV Wilkinson Star Limited Issue 1 January 2014 Product is subject to change without notice...

Reviews: