background image

Do  not  weld  on  coated  metals,  unless  the  coating  is 
removed from the weld area, the area is well ventilated, and 
while  wearing  an  air-supplied  respirator.  The  coatings  on 
many metals can give o

 toxic fumes if welded.

Prevention against burns and radiation

Arc  rays  from  the  welding  process  produce  intense,  visible 
and invisible (ultraviolet and infrared) rays that can burn eyes 
and skin. 

Wear an approved welding helmet fitted with a proper shade 
of filter lens to protect your face and eyes when welding or 
watching 

Wear  approved  safety  glasses  with  side  shields  under  your 
helmet. 

Never use broken or faulty welding helmets.

Always  ensure  there  are  adequate  protective  screens  or 
barriers  to  protect  others  from  flash,  glare  and  sparks  from 
the  welding  area.  Ensure  that  there  are  adequate  warnings 
that welding or cutting is taking place. 

Wear suitable protective flame resistant clothing.

The sparks and spatter from welding, hot work pieces, and 
hot equipment can cause fires and burns

Welding  on  closed  containers,  such  as  tanks,  drums,  or 
pipes, can cause them to explode. 

Accidental  contact  of  electrode  to  metal  objects  can  cause 
arcs, explosion, overheating, or fire. 

Check and be sure the area is safe and clear of inflammable 
material before carrying out any welding.

Protection against noise

Some welding and cutting operations may produce noise.

Wear safety ear protection to protect your hearing.

Protection from moving parts

When  the  machine  is  in  operation  keep  away  from  moving 
parts  such  as  motors  and  fans.  Moving  parts,  such  as  the 
fan, may cut fingers and hands and snag garments.

Protections and coverings may be removed for maintenance 
and  controls  only  by  qualified  personnel,  after  first 
disconnecting the power supply cable.

Replace  the  coverings  and  protections  and  close  all  doors 
when  the  intervention  is  finished,  and  before  starting  the 
equipment.

Take care to avoid getting fingers trapped when loading and 
feeding wire during set up and operation.

When  feeding  wire  be  careful  to  avoid  pointing  it  at  other 
people or toward your body.

Always ensure machine covers and protective devices are in 
operation.

Precautions against fire and explosion

Avoid  causing  fires  due  to  sparks  and  hot  waste  or  molten 
metal

Ensure that appropriate fire safety devices are available near 
the cutting / welding area.

Remove  all  flammable  and  combustible  materials  from  the 
cutting / welding zone and surrounding areas 

Do not cut/weld fuel and lubricant containers, even if empty. 
These  must  be  carefully  cleaned  before  they  can  be  cut/
welded.

Always allow the cut/welded material to cool before touching 
it  or  placing  it  in  contact  with  combustible  or  flammable 
material.

Do  not  work  in  atmospheres  with  high  concentrations  of 
combustible fumes, flammable gases and dust.

Always  check  the  work  area  half  an  hour  after  cutting  to 

make sure that no fires have begun.

Risks due to magnetic fields

The magnetic fields created by high currents may a

ect the 

operation of pacemakers or electronically controlled medical 
equipment. 

Wearers  of  vital  electronic  equipment    should  consult  their 
physician before beginning any arc welding, cutting, gouging 
or spot welding operations.

Do  not  go  near  welding  equipment  with  any  sensitive 
electronic  equipment  as  the  magnetic  fields  may  cause 
damage.

3

Summary of Contents for TIG 200 Dual Voltage

Page 1: ...Operator Manual www jasic co uk TIG Series TIG 180 JT 180 TIG 180 Dual Voltage JT 180DV TIG 200 JT 200 TIG 200 Dual Voltage JT 200DV...

Page 2: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Page 3: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Page 4: ...an may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Replac...

Page 5: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Page 6: ...ow gas function Self adaptive arc force technology improves the performance of the machine when using long cable welding Excellent HF arc ignition High reliability arc striking Advanced arc ignition b...

Page 7: ...cle 35 35 35 35 35 35 No load voltage MMA V 60 60 60 60 60 60 No load voltage TIG V 65 65 65 65 65 65 Downslope time Downslope time s 0 10 0 10 0 10 0 10 0 10 0 10 Post flow time Post flow time s 0 15...

Page 8: ...e work clamp 6 output terminal To connect the TIG torch 7 Torch switch plug connection 8 Gas terminal To connect the gas hose of the TIG torch 9 2T 4T switch When the toggle switch is switched to 4T s...

Page 9: ...de polarity In general when using manual arc welding electrodes the electrode holder is connected the the positive terminal and the work return to the negative terminal Always consult the electrode ma...

Page 10: ...pens and HF arc ignition starts Keep the torch 2 4mm away from the work piece to ignite the arc When the arc is established the HF stops and current rises to the preset value Release the torch trigger...

Page 11: ...and copper Black Gas nozzle diameter mm Electrode diameter mm 6 4 0 5 8 1 0 9 5 1 6 or 2 4 11 1 3 2 Work piece thickness mm Joint form Tungsten electrode diameter mm Welding wire diameter mm Argon ga...

Page 12: ...e inside of arc welding machine Especially check for build up of dust debris on intake grills main voltage transformer inductance IGBT module the fast recover diode and PCB etc Take care when blowing...

Page 13: ...ins voltage is too low Welding can be carried out after the mains voltage recovers The no load voltage is 0 and the under voltage LED is on The mains voltage is too low Welding can be carried out afte...

Page 14: ...Electrical schematic 7 13...

Page 15: ...Parts list 8 14...

Page 16: ...137 TGI180 Dual voltage electrolytic capacitor 10 10021853 Quick socket 30 10006650 TIG180 TIG 180 Dual voltage silicon bridge 11 10043469 Front Panel 30 10037485 TIG200 Silicon bridge board 12 100420...

Page 17: ...DC TIG Series DC TIG MMA WELDING MACHINE Order code TIG180 JT 180 TIG200 JT 200 TIG180 JT 180DV TIG200 JT 200DV Wilkinson Star Limited Issue 1 January 2014 Product is subject to change without notice...