Page 30
remote controller types. See the description of remote controller for specific
operation.
i. MIG synergic function switching
1) In MIG mode, press the "Synergic" function key
to enable or disable the function.
2) If the indicator is on, it indicates that the "Synergic" function is enabled. If it is off, it
indicates that the function is disabled.
3) In "Synergic" mode, the machine automatically matches the welding parameters according
to the current/wire feed speed/plate thi welding type + welding wire diameter
settings.
j. Inching feeding function switching
1) In MIG mode, press the inching feeding key
to enable the function and release the
key to disable it.
2) If the indicator is on, it indicates that the inching feeding is enabled to start wire feeding,
and the wire feed speed depends on the preset value.
k. Gas check function switching
1) In MIG mode, press the gas check function key
to enable or disable the function.
2) If the indicator is on, it indicates that the gas check function is enabled and the gas
valve is open.
Note: The gas check function automatically stops after 20s to avoid gas waste.
l. Parameter adjustment knob A
1) In MIG mode, if the "Synergic" function is disabled, the wire feed speed can be set.
If the function is enabled, rotate the knob to switch display of current, wire feed speed and
plate thickness for configuration.
2) In MMA or Lift TIG mode, the current parameter can be configured.
Summary of Contents for MIG160PFC
Page 5: ......
Page 59: ...Page 59 Appendix 2 List of common spare parts List of common spare parts 1 MIG160 MIG200...
Page 61: ...Page 61 List of common spare parts 2 MIG160PFC MIG200PFC...
Page 63: ...Page 63 List of common spare parts 3 MIG250...
Page 66: ...Page 66 List of common spare parts 4 MIG250PFC...
Page 70: ...Page 70...