specifications and
installation instructions
Model 1000--FS
page 9 of 16
®
JARVIS
PRODUCTS CORPORATION
33 ANDERSON ROAD, MIDDLETOWN, CONNECTICUT 06457--4926
UNITED STATES OF AMERICA
TEL. 860--347--7271 FAX. 860--347--6978
6207001:::
SPECIFICATIONS
Model 1000--FS
Motor Power
8 hp
5966 W
Blade Speed
at 7.6 gpm or 28.8 Lpm
2150 rpm
Control Handle
dual / electric
Blade Diameter
9.0 in
229 mm
10.5 in
267 mm
12.0 in
305 mm
Cutting Depth
with 9.0 in blade
3.0 in
76 mm
with 10.5 in blade
3.75 in
95 mm
with 12.0 in blade
4.5 in
114 mm
Overall Length (12.0 in bl.)
26 in
660 mm
Weight
41 lbs
18.6 kg
Vibration
less than (<) 122 dB
<1.26 m/sec
2
Noise (one meter from tool)
88 dB
Hydraulic Power Unit
Motor Power
10 hp
7457 W
Operating Voltage
230/460 V std
3 ph, 60 Hz
other voltages and 50 Hz available
Hose Length
16 ft
5 m
Flow Rate
7.6 gal/min
28.8 L/min
Oil Capacity
30 gal
114 L
Oil Visc. at 100
°
F/40
°
C
200 SUS
46 ISO
Overall Dimensions (lxwx h)
37.6 x 27.2 x 31.5 in
955 x 691 x 800 mm
Weight (without oil)
408 lb
185 kg
INSTALLATION INSTRUCTIONS
ALWAYS DISCONNECT THE HYDRAULIC HOSES
AND SHUT THE POWER OFF IN ACCORDANCE
WITH OSHA’S LOCKOUT/TAGOUT PROCE-
DURES (29 CFR 1910.147) BEFORE PERFORM-
ING ANY REPAIRS OR MAINTENANCE.
Refer to Figure B on page 5 for referenced items unless
otherwise noted. Use Figure D on page 7 and Figure 1
on page 10 as a guide for wiring and hose connections
to the hydraulic power unit.
1 Install the hydraulic power unit overhead or on the
floor behind the work station.
1.1 Avoid excessive height and long pipe runs.
1.2 Locate the equipment in a clean, dry work area
and provide adequate space on all sides of the
unit for maintenance accessibility to all compo-
nents.
2 Remove breather filler cap (item 9, Figure D, page
7) and fill the power unit oil reservoir with a USDA
approved premium grade hydraulic fluid (viscosity
index 200 SUS at 100
°
F / 46 ISO at 40
°
C ).
Never
run the power unit without oil.
3 Install the balancer,
Jarvi
s part number 4042004,
above the work station.
3.1 If the operator has to move with the chain line,
install the balancer on a trolley. The trolley
should have sufficient travel to allow the opera-
tor to reach the entire work area.
4 Suspend the 1000--FS from the balancer.
4.1 Adjust the balancer to the operators preference.
5 Make all necessary wiring connections.
All wiring
must be done in accordance with national, state
and local electrical codes.
Refer to wiring diagram
inside the electrical control box cover.
5.1 Domestic power units require three--phase, 60
hertz, 230/460 volts to the motor and 115 volts,
single--phase to the electrical control box.
Please check the wiring diagram inside the cov-
er of your electrical control box for other volt-
ages and frequencies.
5.2 Equip the power unit with a switch at the opera-
tors station to facilitate shut down in case of
equipment failure.
5.3 Plug the wire and plug assembly (item 71) on the
1000--FS saw into the twist lock plug outlet
(item 5, Figure E, page 8) on the electrical con-
trol box.
6 Make all necessary hose connections. Connect the
hydraulic pressure and return lines.
6.1 Connect the quick connect socket (item 82) on
the 1000--FS saw to the return line quick connect
plug (item 25, Figure D, page 7) of the power
unit. Connect the the pressure line quick con-
nect socket (item 24, Figure D, page 7) on the
power unit, to the quick connect plug (item 80)
of the 1000--FS saw.