en 11
The operator light switches on in the following cases:
1. First turning on of the door opener (short)
2. Power interruption (short)
3. With each turning on of the door opener.
The light turns off automatically after 2 1/2 minutes.
Maintenance of the door opener
A proper installation ensures the optimum performance of the door ope-
ner with minimum maintenance. An additional lubrication is not required.
Gross dirt accumulation in the guide rail may impair the function and
must be removed.
Clean the drive head, wall switch and remote control with a soft, dry
cloth. Do not use liquids.
Before any maintenance, cleaning and related mainte-
nance work, the mains supply plug should be pulled out.
Danger from electric shock!
33
34
35
Attach warning labels
Cleaning and maintenance
Cleaning
Limit switch adjustment and force regulation:
These settings must be checked and undertaken properly during the
installation of the opener. Due to weathering, minor changes can occur
during operation of the opener that need to be addressed by a new setting.
This can particularly happen in the first year of operation.
Follow the instructions for setting travel limits and force (refer to section 23 and
33) carefully and re-check the automatic safety reverse after each resetting.
Once a month:
• Check automatic safety reverse again and reset if necessary.
• Operate door manually. If the door is unbalanced or stuck, please
contact the service centre.
• Check for complete opening and closing of the door. Where appro-
priate, readjust limit switches and / or power.
Twice a year:
•
Check the belt tension. For this, first disconnect the carriage from the
drive. If necessary, adjust belt tension.
Once a year (at the door):
• Lubricate door roller, bearings and joints. An additional lubrication of
the door opener is not required.
36
Maintenance
Check the system often, especially cables, springs and fas-
teners, for signs of wear, damage or lack of balance. Do not
use if repair or adjustment work must be performed, because
an error in the system or an incorrectly balanced door may cause injury.
Repairs to electrical equipment and gates may be carried out only by an
authorized specialist / expert. In any case, please do not ever carry out
repairs yourselves because this could result in serious injury or death.
Battery of the remote control:
The batteries in the remote have an extremely long life.
If the transmission range decreases, the batteries must be replaced.
Batteries are not covered by the guarantee.
Please observe the following instructions for battery:
Batteries should not be treated as household waste. All consumers
are required by law to dispose of batteries properly at the designated
collection points. Never recharge batteries that are not meant to be
recharged.
Danger of explosion!
Keep batteries away from children, do not short-circuit them or take
them apart. See a doctor immediately, if a battery is swallowed. If ne-
cessary, clean contacts on battery and devices before loading. Remove
exhausted batteries from the device immediately!
Increased risk of leakage!
Never expose batteries to excessive heat such as sunshine,
fire or the like! There is increased risk of leakage!
Never expose batteries to excessive heat such as sunshine, fire or the
like! There is increased risk of leakage!
Avoid contact with skin, eyes and mucous membranes. Rinse the parts
affected by battery acid with plenty of cold water and consult a doctor
immediately. Use only batteries of the same type.
Remove the batteries if the device is not being used for a long time.
Replacing battery:
To replace battery, turn remote control around and open the case with a
screwdriver. Lift cover and lift control board below. Slide battery to one
side and remove. Watch polarity of battery!
Assemble again from in reverse direction.
ATTENTION!
Danger of explosion if battery is replaced improperly.
Replacement only by identical or equivalent type (CR2032).
37
Replace batteries of the remote control
The LED lighting has a very long life and is maintenance free.
The lens cover cannot be removed.
38
Operator light