REX F-1-9 and REX F-3-9 – Standalone or Access Controller
3/2015
Black line
www.jantar.si
5. beep
Sound is ON
Tamper is OFF
Door status switch input-normally closed (NC)
Time is set in seconds
6. beep
Sound is OFF
Tamper is ON
Door status switch input-normally closed (NC)
Time is set in seconds
7. beep
Sound is ON
Tamper is ON
Door status switch input-normally closed (NC)
Time is set in seconds
8. beep
Sound is OFF
Tamper is OFF
Door status switch input- normally opened (NO)
Time is set in minutes
9. beep
Sound is ON
Tamper is OFF
Door status switch input- normally opened (NO)
Time is set in minutes
10. beep
Sound is OFF
Tamper is ON
Door status switch input- normally opened (NO)
Time is set in minutes
11. beep
Sound is ON
Tamper is ON
Door status switch input- normally opened (NO)
Time is set in minutes
12. beep
Sound is OFF
Tamper is OFF
Door status switch input- normally closed (NC)
Time is set in minutes
13. beep
Sound is ON
Tamper is OFF
Door status switch input- normally closed (NC)
Time is set in minutes
14. beep
Sound is OFF
Tamper is ON
Door status switch input- normally closed (NC)
Time is set in minutes
15. beep
Sound is ON
Tamper is ON
Door status switch input- normally closed (NC)
Time is set in minutes
Function 16) Reset
“HARD” reset. Use it instead off manual reset (power off/on).
Reset with master fingerprint:
Place the master fingerprint sixteen times on the sensor and remove it (16
double beeps).The controller will start to beep every second. After three
beeps place a user fingerprint on the sensor or approach a user card for
confirmation.
Reset with master card:
Approach the master card and remove it after 16 double beeps. The
controller will start to beep every second. After three beeps approach a user
card or place a user fingerprint on the sensor for confirmation.
AS AN ACCESS CONTROLLER
As an access controller, it is intended for controlling entries, exits and passes
of users in the system and controlling sliding doors, ramp, el. strike, turning
alarm on/off… It needs to be set with CODEKS software.
The controller switches to access controller when tables are sent by
the software or when it is set to mode 4 with function 9. Change the
controller’s address from 255 to any number between 1 and 254. If
you have more controllers on the communication line, don’t duplicate
addresses. Add them one by one on the communication line, because
every controller has address 255 by default.
Communication
Connect the controller to the computer with one of the power supplies, with
built-in communication converter, from the Spider family: Spider W5-USB,
Spider W5-NET, Spider W40+NET.
The RS485 communication bus is used between the controllers and Jantar
software. Up to 128 controllers can be lined up into one communication line.
The maximum length of the communication line is 1000 cable meters. It is
recommended that you use an FTP or S-FTP cable. Only a serial connection
of controllers in a single communication line is allowed.
Star (parallel)
connection is not allowed
.
All shields of S-FTP cables must be wired together and at
one point
connected to the earth. Individual connections to the earth are not allowed.
Do not connect the shield of the cable to the ground of the controller.
In the event of problems in communication, a termination resistor
needs to be added. We recommend using 120 Ohm resistors on each
side of the cable. Converters are, on the RS485 side, protected with
slow-blow fuses and transient voltage suppressors.
Changing back to standalone controller from access
controller:
In the Codeks Device Manager software do the “Brainwash” of the controller.
Address of the controller’s switches back to 255.
Correct and incorrect position of the finger on the sensor
Correct: Incorrect:
ORDERING CODES
REX
[box]-[card]-[software]
Box:
F
Card:
1
– reading frequency 125kHz (cards)
3
– reading frequency 13.56MHz (cards)
Software:
9
– CODEKS
Code
Description
REX F-1-9
Standalone or access controller in
F
box, with fingerprint
reader, integrated proximity card reader frequency
125kHz, for CODEKS software
REX F-3-9
Standalone or access controller in
F
box, with fingerprint
reader, integrated proximity card reader frequency
13.56MHz, for CODEKS software
OTHER
Warranty only applies when the controller Rex is used with power supply
or/and communication converter from the Spider family.
Please read through our warranty and disclaimer statements.
Connection scheme and additional support for the use of this product can be
found on:
CONTACT:
Jantar d.o.o.
Kranjska cesta 24
4202 Naklo
SLOVENIA