AS A STANDALONE CONTROLLER 

 

The entire set-up procedure is carried out with the master fingerprint or 
master card. You can register two master fingerprints or two master cards.  
You can also register one master fingerprint and one master card. 
 

The master fingerprints or master cards cannot be replaced or 
duplicated. You cannot change any setting without them and neither 
can we.

  

 

Programming with the master fingerprint or master 
card 

 

First connection to the power supply and registration of the 

master fingerprints or master cards 

Register master fingerprints: 

Turn on the power supply (2 beeps indicate power on) and place your 
fingerprint on the sensor, which you have chosen to be the master 
fingerprint. After the triple beep remove the fingerprint. LEDs will begin to 

flash rapidly, indicating recording fingerprint. At the end of the recording, 
when the controller starts beeping rapidly, once again place the fingerprint 
on the sensor. If the fingerprint is identical to the first one, controller 
confirms the successful registration with a double beep and with the flashing 
green LED diode. If the registration has failed the controller signals with a 
longer beep. If the registration is successful repeat the process for the 
second master fingerprint. 

 

Register master cards: 

Turn the power supply on (2 beeps indicate power on). One by one approach 
two cards you will use as a master cards (3 beeps indicate a successful 
registration). The first two cards registered become 

master cards. 

All the 

other cards will be registered as 

users (user cards)

.  

 

If you want to register only one master fingerprint, then register the 
same fingerprint twice. You can register only one master card if you 
approach the same card twice. You can also register one master 
fingerprint and one master card. 

 

Usage of master fingerprint and master card 

With the master fingerprint or master card you choose the programming 
function. Functions can be confirmed either with user fingerprint or user 
card. 

Master fingerprint: 

Every time you place the master fingerprint on the sensor you hear one beep 
(successfully read) and a double beep (programming function). To select the 
different programming functions you need to remove your master fingerprint 
after the double-beep and place it again on the sensor within 2 seconds. The 
number  of double beeps indicates the programming function. 

Master cards: 

If  you  hold  the  master  card  in  front  of  the  controller,  every 2  seconds a 
double beep is heard.  The number  of double beeps indicates the 
programming function. 

 

 

PROGRAMMING FUNCTIONS WITH MASTER FINGERPRINT 

OR MASTER CARD 

Function 

Description 

Register or delete user fingerprints and cards 

Pulse time/ Duration of active output or toggle mode  

Door status switch input/ Time till pre-alarm 

Duration of pre-alarm 

Negate / Switch output state 

Delete fingerprint or lost card 

Delete fingerprint or lost card 

Switch to Wiegand 26-bit or access controller 

13 

Delete all 

15 

Sound (off/on), alarm output (off/on), door status switch 
input NC or NO, set time in minutes or seconds 

16 

Reset 

 
 

Description of programming functions 

 

Function 1) User fingerprints and user cards 

Register or delete user fingerprints and cards. With a registered fingerprint 

or card, output (O0, wire 3) for an el. strike is triggered for the time set in 
the function 2. In the controller, registered fingerprints and cards are 
arranged in order of their registration. Every registered fingerprint and card 
is saved to its own position. 
For registration or deletion of user fingerprints and cards you can use the 
master fingerprint 

or

 card. 

Register user fingerprint with master fingerprint: 

Place the master fingerprint on the sensor and remove it (1 double beep). 
Within a period of 10 seconds place a user fingerprint on the sensor. Remove 
it after the beep. LEDs will begin to flash rapidly, indicating recording 
fingerprint. At the end of the recording, when the controller starts beeping 
rapidly, once again place the fingerprint on the sensor. If the fingerprint is 
identical to the first one, controller confirms the successful registration with a 
lit green LED and activated output. If the registration has failed the controller 
signals with a longer beep. If the registration is successful, the user 

fingerprint is registered and with it, the user can open output on the 
controller. If you repeat the process with the same fingerprint, this 
fingerprint will be deleted. Next registered fingerprint (or card) will take the 
first available position on the list or position of the deleted fingerprint. If you 
would like to delete the fingerprint of the user that no longer exists, you 
must maintain a list of registered fingerprints and cards, arranged in order of 
registrations-positions (functions 6 and 7). 

 

Register user card with master card: 

Approach the master card and remove it after 1 double beep. Within a period 

of three seconds approach a user card. You can register more cards at once, 
if you approach them one by one. The user card is now registered and with 
it, you can open output on the controller. If the card has already been 
registered, it is now deleted and its position is now empty. Next registered 
card (or fingerprint) will take the first available position on the list or position 
of the deleted card. When you have register/deleted all of the cards, wait 
until the controller confirms it with double beep. To delete a lost user card, 
you must maintain a list of registered cards and fingerprints, arranged in 
order of registrations-positions (functions 6 and 7).  

 

Function 2) Pulse time/ Duration of active output or toggle 

mode 

Set the duration of active output/ the time in which you can open the door or 
set output to toggle mode. The time can be set in seconds or minutes. 
Switching time from seconds to minutes and back, can be adjusted by using 
the function 15. Toggle mode means, if a user fingerprint or card is 
registered, output will remain opened (if it was closed) or closed (if it was 
open) till next registration.  

Set the duration of active output with master fingerprint: 

Place the master fingerprint two times on the sensor and remove it (2 double 
beeps). The controller will start to beep every second. Each beep indicates 1 

second or 1 minute of active output. Duration of active output can be max 
120 seconds or 60 minutes. When you hear the required number of beeps, 
place a user fingerprint on the sensor or approach a user card for 
confirmation. 

Set toggle mode with master fingerprint: 

Place the master fingerprint two times on the sensor and remove it (2 double 
beeps). Place a user fingerprint on the sensor or approach a user card before 
the first beep. 

 

 

Set the duration of active output with master card: 

Approach the master card and remove it after 2 double beeps. The controller 
will start to beep every second. Each beep indicates 1 second or 1 minute of 
active output. Duration of active output can be max. 120 seconds or 60 
minutes. When you hear the required number of beeps, approach a user card 
or place a user fingerprint on the sensor for confirmation. 

Set toggle mode with master card: 

Approach the master card and remove it after 2 double beeps. Approach a 
user card or place a user fingerprint on the sensor before the first beep. 
Toggle mode is selected.

 

 

Function 3) Door status switch input 

Set the time till pre-alarm / time in which the door can stay open, without 
triggering the pre-alarm and consequently the alarm. This function is used 
when the door status switch on el. strike is connected to Input0/I0/wire 5 on 
the controller. The input is normally opened (NO) by default. It can be 
changed to normally closed (NC) by using the function 15. The time can be 
set in seconds or minutes. Switching time from seconds to minutes and back, 
can be adjusted by using the function 15. 

Set the time till pre-alarm with master fingerprint:  

Place the master fingerprint three times on the sensor and remove it (3 

double beeps). The controller will start to beep every second. Each beep 
indicates 1 second or 1 minute till pre-alarm. Duration of the time till pre-
alarm can be max 120 seconds or 60 minutes. When you hear the required 
number of beeps, place a user fingerprint on the sensor or approach a user 
card for confirmation. 

 
Set the time till pre-alarm with master card:  

Approach the master card and remove it after 3 double beeps. The controller 
will start to beep every second. Each beep indicates 1 second or 1 minute till 

pre-alarm. Duration of the time till pre-alarm can be max. 120 seconds or 60 
minutes. When you hear the required number of beeps, approach a user card 
or place a user fingerprint on the sensor for confirmation. 

 

Summary of Contents for REX F-0-9

Page 1: ... of UTP cables for the positive pole and one for the negative pole The cable length between power supply and the controller should not exceed 50m Take into consideration that a 0 22mm2 cable has a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greate...

Page 2: ...e process with the same fingerprint this fingerprint will be deleted Next registered fingerprint will take the first available position on the list or position of the deleted fingerprint If you would like to delete the fingerprint of the user that no longer exists you must maintain a list of registered fingerprints arranged in order of registrations positions functions 6 and 7 Function 2 Pulse tim...

Page 3: ...place a user fingerprint on the sensor confirmation Delete all with the Codeks Device Manager program Set the Rex to the default settings by using the Codeks Device Manager program Connect the Rex via RS485 communication line to the Spider communication converter USB or NET Connect the Spider to the computer In Codeks Device Manager find the device and perform the Brain Wash function which sets th...

Page 4: ...d Jantar software Up to 128 controllers can be lined up into one communication line The maximum length of the communication line is 1000 cable meters It is recommended that you use an FTP or S FTP cable Only a serial connection of controllers in a single communication line is allowed Star parallel connection is not allowed All shields of S FTP cables must be wired together and at one point connect...

Page 5: ...of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greater distances a thicker cable of 0 5mm2 or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm2 cable voltage drop will be 4 5V at 100m For the device with 60mA consumption the voltage drop is 0 5V Reading distance depends on where the controller ...

Page 6: ...led the controller signals with a longer beep If the registration is successful the user fingerprint is registered and with it the user can open output on the controller If you repeat the process with the same fingerprint this fingerprint will be deleted Next registered fingerprint or card will take the first available position on the list or position of the deleted fingerprint If you would like t...

Page 7: ... sensor or approach a card which was registered after the one you wish to delete This will delete the previous fingerprint or card on the list Next registered fingerprint or card will take the position of a deleted fingerprint or deleted card Delete a fingerprint or a lost card with master card Approach the master card and remove it after 7 double beeps Within a period of three seconds approach th...

Page 8: ... 255 to any number between 1 and 254 If you have more controllers on the communication line don t duplicate addresses Add them one by one on the communication line because every controller has address 255 by default Communication Connect the controller to the computer with one of the power supplies with built in communication converter from the Spider family Spider W5 USB Spider W5 NET Spider W40 ...

Reviews: