21 : Acceleration and
deceleration prohibited
22 : PID pause
23 : PLC status reset
24 : Wobble frequency
pause
25 : Counter input
26 : Counter reset
27: Length count input
28: Length reset
29 : Torque control
prohibited
30 : PLUSE pulse frequency
input (DI5)
31 : Reserved
32 : Immediate DC braking
33 : External fault normally
closed input
34 : Frequency modification
enabled
35 : PID action direction
reversed
36 : External stop terminal 1
37 : Switching of running
command Terminal 2
38 : PID integral pause
39 : Switching between
frequency source X and
preset frequency
40 : Switching between
frequency source Y and
preset frequency
43 : Switching between PID
parameters
44 : User-defined fault 1
45 : User-defined fault 2
46 : speed control/torque
control switching
47 : emergency stop
48 : external stop terminal 2
49 : deceleration DC braking
50 : clear the current
running time
51: Two-wire and three-wire
switching
52: No reverse
53: Single terminal
UP/DOWN enable ,
frequency source switching
( same as function 18 )
54: Terminal active UP
Inactive is DOWN
P4-04
DI5 terminal function
selection
12
★
62468
P4-05
reserve
00
★
62469
P4-06
reserve
00
★
62470
Function
code
Name
Setting range
Factory
default
Attrib
utes
DEC
address
P4-10
DI terminal filter time
0.000s
~
1.000s
0.010s
☆
62474
P4-11
Terminal command
0: Two-line
2: Three-
0
★
62475
6
Janson Controls Technologies(Shenzhen) Co.,Limited
Chapter6 Brief Introduction of Function Parameters
FC100P Series Manual V1.0
-35