Programmable input and
output terminals
Input terminal function can be edited, output terminal function can be edited
Process PID adjustment
function
Built-in process PID module
Simple PLC function
Built-in simple PLC module, which can realize timing and multi-segment
frequency output
Textile Wobble Function
Built-in textile swing frequency function module
Protective function
Overvoltage stall
Bus voltage automatic control to prevent overvoltage faults
Automatic current limiting
protection
Output current is automatically limited to prevent over-current faults
Overload pre-alarm and alarm
Overload early warning and protection
Input and output phase loss
protection
Input and output phase loss automatic detection and alarm function
Overvoltage and overflow stall
control
Automatically limit the current and voltage during operation to prevent
frequent over-current and over-voltage trips
Output Short-to-Ground
Protection
Output to ground short-circuit effective protection function
Output phase-to-phase short
circuit protection
Output interphase short circuit effective protection function
input Output
External analog power supply
+10V, load capacity 100mA
External digital power supply
+24V, load capacity 200mA
analog input
AI1: voltage 0-10V / 0-20mA
A I2 : voltage 0-10V / 0-20mA
analog output
AO1: 0-10V/0-20mA (voltage/current optional)
AO 2 : 0-10V (voltage output)
digital input
DI1
-
DI 5 ( DI 5 can be selected as a high-speed pulse signal)
digital output
FM , AO2 , FM can be selected as high-frequency pulse signal output
Relay output
TA/TB/TC and RA/RB/RC : Contact capacity 250VAC/3A or 30VDC/1A
M UDBUS communication
A + , B-
operation display
LED display
5 digit double LED digital tube
Set frequency, output frequency, output voltage, output current, motor
speed, output torque, digital terminals, status parameters, programming
menu parameters and fault codes, etc.
indicator light
3 unit indicators, 4 status indicators
Environmental characteristics
Working temperature
-10
-
+40
℃
, the highest is 50
℃
, the air temperature change is less than
0.5
℃
/min
40-50
℃
needs to be derated for use: the output current is derated by 2% for
every 1
℃
storage environment
temperature
-40
-
+70
℃
place of use
Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist,
water vapor, dripping water or salt, etc.
Altitude
Less than 1000 meters, derating is required for more than 1000 meters
humidity
Less than 95%RH, no condensation
Vibration resistance
3.5m/s
2
at 2-9Hz, 10m/s
2 at 9-200Hz
(IEC60721-3-3)
degree of protection
IP20
pollution level
Class 2 (dry, non-conductive dust pollution)
2