Care of Your Machine

25. Cleaning the Feed Dog

Remove the needle and presser foot.
Remove the 2 setscrews and remove the needle plate.

Clean out dust and lint clogging on the feed dog with a
lint brush.
Replace the needle plate and secure it with the
setscrew.

26. Dismantling and Assembling the Hook Race

Raise the needle to its highest position
and open the hook cover. Open the
bobbin case latch and pull out the
bobbin case out from the machine.

Open the hook race ring holders.
Rremove the hook race ring.
Take out the hook race ring and
shuttle hook.

Clean the hook race with a lint brush
and soft dry cloth.
Clean the shuttle hook.
Replace all the parts by following the
procedure in reverse.

Troubleshooting

Hook race ring holder

Screws

See No. 6
See No.11
See No. 3
See No. 3
See No. 12

Problem

The needle thread breaks.

The biobbin thread breaks.

The needle breaks.

Skipped stitches

Seam puckering

Stitches form loops on the
wrong side of the fabric.

The cloth is not feeding.

Noisy operation

Cause

Reference

1. The needle thread is not threaded properly.
2. Needle thread tension is too tight.
3. The needle is bent or blunt.
4. The needle is incorrectly inserted.
5. The thread is either too heavy or too fine for the needle.

1. The bobbin thread is not threaded properly.
2. The bobbin thread is too tight.
3. Lint has collected in the bobbin case.

1. The needle is incorrectly inserted.
2. The stitch selector has been turned when the needle is in  the fabric.
3. The needle is too fine for the fabric being sewn.

1. The needle is incorrectly inserted or bent.
2. The needle and/or thread is not suitable for the fabric being sewn.
3. The Blue Tipped needle is not used when sewing stretch, very fine or
    synthetic fabrics.
4. The needle thread is not threaded properly.

1. The needle thread tension or bobbin thread tension is too tight.
2. The needle and/or bobbin thread are not threaded properly.

1. The needle thread tension is too loose.
2. The needle is either too heavy or too fine for the thread.
3. The needle and/or bobbin thread are not threaded properly.

1. The feed dog or shuttle hook is packed with lint.
2. The shuttle hook needs oiling.

1. The feed dog is packed with lint.

See No. 6
See No. 13
See No. 25

See No. 3
See No. 8
See No. 12

See No. 3
See No. 12
See No. 12

See No. 6

See No. 11
See No. 6

See No. 11
See No. 12
See No. 6

See No. 12

See No. 12
See No. 13

639-800-464 (E)  Printed in Thailand

Summary of Contents for HF106

Page 1: ...r electrical or mechanical adjustment 4 Never operate the appliance with any air opening blocked Keep ventilation openings of this sewing machine and foot controller free from accumulation of lint dus...

Page 2: ...ol the faster the machine runs 3 Free Arm Sewing 4 Power Connection The presser foot lifter raises and lowers the presser foot You can raise it about 1 4 higher than normal up position This helps when...

Page 3: ...ll the handwheel out to the right 2 Pull the thread from the spool and draw it around the thread guides 3 Draw the thread through the hole on the bobbin from the inside to outside put the bobbin on th...

Page 4: ...ide as shown Draw the thread around the thread guide plate as shown Pull the thread up then draw it through the thread take up lever as shown Draw the thread and slip it into the needle bar thread gui...

Page 5: ...e handwheel toward you to bring the needle down into the fabric Raise the presser foot Pivot the fabric aroumd the needle to change sewing direction as shown Finishing sewing To fasten seam ends press...

Page 6: ...the machine when you are directly opposite the first stitch on the left hand side 5 Raise the needle and select Sew 5 stitches of bartack and raise the needle out from the fabric 6 Raise the presser...

Page 7: ...read is too tight Needle thread is too loose Decrease tension Increase tension 24 Selecting Needles and Threads In general fine threads and needle are used for sewing thin fabrics and thicker threads...

Page 8: ...o tight 3 The needle is bent or blunt 4 The needle is incorrectly inserted 5 The thread is either too heavy or too fine for the needle 1 The bobbin thread is not threaded properly 2 The bobbin thread...

Reviews: