Reading out recordings

If you wish to read out the measured data, connect 
the measurement case to a PC via the Ethernet 
connection 

(7) 

. The read-out is implemented via 

the GridVis

®

 software. 

MRG 96RM-E Flex RCM views

- 5 -

Power Analyser
UMG 96RM-E

Measurement 
transducer

Current transformer 
inputs 

L1

, I 

L2

, I 

L3

, I 

N

Supply voltage

AUX

24V DC 1A

I L

1

Current transformer inputs 

UMG 96 RM

L1

L2

L3

N

I L

3

I L

2

N

Ethernet

I L

5

I L

6

Residual current measurement

1.

5.

3.

2.

Voltage inputs
U

 L1

, U

 L2

, U

 L3

, U

 LN

4.

Ethernet
connection
RJ45

7.

Residual current 
transformer inputs

5

, I 

6

6.

Summary of Contents for MRG 96RM-E Flex RCM

Page 1: ...bH Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Fax 49 6441 9642 30 E mail info janitza com Internet http www janitza com www janitza com Mobile universal measurement device MRG 96RM...

Page 2: ...basic device 4 Connecting the measurement case 4 Reading out recordings 5 MRG 96RM E Flex RCM views 5 Measurement transformer settings 6 Example connection voltage measurement 7 Example connection cu...

Page 3: ...Do not work with the device if the front plate has been removed Otherwise you may come into contact with hazardous voltages It is not permitted to use the device with the front plate removed The UMG 9...

Page 4: ...ered by this operation manual for the UMG 96RM E please contact the support department of Janitza electronics GmbH Tel no 49 6441 9642 22 This device must only be operated and repaired by specialised...

Page 5: ...MRG 96RM E Flex RCM views 5 Power Analyser UMG 96RM E Measurement transducer Current transformer inputs I L1 I L2 I L3 I N Supply voltage AUX 24V DC 1A I L1 Current transformer inputs UMG 96 RM L1 L2...

Page 6: ...A 6 630 A 5 1000 A 4 1500 A 3 2000 A 2 4000 A 1 Setting Rogowski coil 300 mm Flex CT 1A 300 mm Set the current measurement range with the DIP switch 2 in accordance with the table Potentiometer 1 DIP...

Page 7: ...fuse Max 20mm Locking sleeve with bayonet catch for accommodating a fuse Example connection current measurement N L1 L2 L3 PE I1 I2 I3 IN I5 I6 Voltage measurement terms connections Rogowski coil RCM...

Page 8: ...rect setting of the current transformer check the performance values of the individual phases these must not possess any negative signs when drawing energy Also check the power factor for plausibility...

Page 9: ...Power supply 230 V 50 Hz 50 VA Interface Ethernet Measurement inputs See UMG 96RM E operating instructions Measurements See UMG 96RM Eoperating instructions Dimensions L x W x H 350 mm x 295 mm x 150...

Reviews: