background image

Page 4

CAUTION

To avoid costly equipment damage, after verifying 
proper water flow and 

prior

 to putting system into 

normal operating conditions, flush the system using 
Backwash mode until the waste water is clean. 
Refer to 

Section 4

 for Backwash mode operation 

instructions.

Figure 4.  Jandy Versa-Coupler

Alignment 

Mark

Versa-

Coupler 

p/n 8044

CAUTION

Do not let any adhesive get inside the Slide Valve 
body. Adhesive inside the valve body will prevent the 
piston from moving freely, or cause the valve to leak. 

To Pool

(PORT A)

To Waste (PORT E)

From

Pump

(PORT B)

Figure 3.     SVLV8 Installed on Jandy DEL48 or 

(DEL60)

5.      Hold the Slide Valve upright and place onto the 

fi lter bulkheads (see Figure 3).

6.      Tighten both union nuts to secure the valve on the 

fi lter.

7.      Place fi lter and valve in proper location on the 

equipment set pad.

8.      Plumb the discharge of the pump into the Slide 

Valve inlet labeled 

PORT B

.

9.      Plumb the Slide Valve outlet labeled 

PORT A

 to the 

heater or pool return lines.

10.    Plumb the Slide Valve outlet labeled 

PORT E

 to the 

waste line as needed. Allow the connections to dry 
for 24 hours.

NOTE:

  For new installations other than Jandy DEL48 

or DEL60, use the SVLV2 and the Versa 
Coupler Kit, p/n 8044 (See Figure 4).

             If using the Slide Valve with a Pentair 

fi

 lter, use 

Pentair Pool Products™ Union Set #27002, and 
then proceed to section B. If using a Sta-rite 

fi

 lter, use Sta-Rite

® 

Union Set #PKGM188, then 

proceed to section B.

Section 2.  SVLV2 and Versa-Coupler 

Installation

NOTE

   Certain 

fi

 lters may require only one (1) versa-

coupler (p/n 8044).

1.      Slide one versa-coupler into 

PORT C

 and one into 

PORT D

 on the Slide Valve.

2.

     

Hold the Slide Valve up to the fi lter and twist the 
versa-couplers until they slide into the fi lter inlet 
and outlet ports.  

NOTE

   Make sure to align each versa-coupler to the 

fi

 lter and the Slide Valve prior to gluing the 

assembly. When the parts are in alignment, 
mark each piece to ensure correct reassembly.

3.      Remove the valve from the fi lter. Clean the versa-

couplers and glue them onto the valve using the 
alignment marks as a reference.

4.      Clean the versa-coupler and glue onto the fi lter. 

Hold the coupler in place for a minimum of one 
(1) minute.

5.      Plumb the discharge of the pump into the Slide 

Valve inlet labeled 

PORT B

.

CAUTION

The Slide Valve has molded labels on each port (see 
Figure 1). The ports on the SVLV8 are equipped with 
union connections that match the connections on the 
filter ports. Do not use pipe sealants on union nuts.

11.    When the glue is dry, start the system and check 

for proper water fl ow.

To Filter Body
(cut away view)

Filter Outlet
 (PORT C)

Filter Inlet
 (PORT D)

Summary of Contents for Slide Backwash Valve

Page 1: ...and Operation Manual FOR YOUR SAFETY This product must be installed and serviced by authorized personnel qualified in pool spa installation and maintenance Improper installation and or operation will...

Page 2: ......

Page 3: ...e Valve without unions and p n 8044 Versa Coupler Kit The Slide Valve is a two position valve The valve handle must be fully extended or fully depressed This valve can not be throttled To operate the...

Page 4: ...044 See Figure 4 If using the Slide Valve with a Pentair filter use Pentair Pool Products Union Set 27002 and then proceed to section B If using a Sta rite filter use Sta Rite Union Set PKGM188 then p...

Page 5: ...ters Ensure that the Slide Valve handle is fully depressed handle and piston pushed all the way down Turn the handle until the stainless steel pin on the piston locks into the position bracket Sand Fi...

Page 6: ...un the system until the waste water runs clean 5 Turn off the system pump s 6 Return the Slide Valve handle to the normal operating position see Section 3 7 Turn on system pump s and check for normal...

Page 7: ...union nut 10 Return the Slide Valve handle to the normal operating position see Section 3 11 Turn on system pump s and check for normal water flow Section 6 Winterizing Lid O ring Shaft O ring Top Bl...

Page 8: ...n Tail Piece Roll Pin Handle 1 Roll Pin Shaft 13 16 Index Plate Lid 1 1 1 2 1 1 1 R0442100 2 Shaft Replacement Kit Shaft Handle Roll Pin Handle 1 Roll Pin Shaft 13 16 Index Plate Lid Lid Union Nut O r...

Page 9: ...Page 9 NOTES...

Page 10: ...Page 10 NOTES...

Page 11: ......

Page 12: ...at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combusti...

Reviews: