background image

LIMITED WARRANTY

Thank you for purchasing Jandy

®

 pool and spa products. Waterpik Technologies (manufacturer of Jandy  

products, including Laars

®

 pool and spa heaters, Air Energy Heat Pumps, and Clormatic Electronic Chlorine 

Generators) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of 
one year from the date of retail purchase, with the following exceptions:

• AquaLink

®

 RS units installed with Jandy Surge Protection Kits will be covered for two years.

• NeverLube

®

 valves are warranted for the life of pool and/or spa on which they were originally installed.

• AquaPure

TM

 Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have 
been moved from their original installation sites. The liability of Waterpik Technologies shall not exceed the repair 
or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective 
part, transportation to or from the factory, and any other materials required to make the repair. This warranty does 
not cover failures or malfunctions resulting from the following:

1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,

Operation and Maintenance Manuals provided with the product(s).

2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total

Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000 not including salt ppm].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing

sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,

DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Waterpik Technologies. No one is authorized to make any other warranties on 
Waterpik Technologies' behalf. 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A 
PARTICULAR PURPOSE AND MERCHANTABILITY. WATERPIK TECHNOLOGIES EXPRESSLY DISCLAIMS 
AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE 
DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This warranty gives you specific 

legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, 
model number, serial number and date of installation. The installer will contact the factory for instructions 
regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 
available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical 
support department at (707) 776-8200 extension 260. All returned parts must have a Returned Material 
Authorization number to be evaluated under the terms of this warranty.

6000 Condor Drive • Moorpark, CA USA 93021

480 S. Service Road West • Oakville, Ontario, Canada L6K 2H4

A Waterpik Technologies Company

 • 707.776.8200 • Fax 707.763.7785
 • 905.844.8233 • Fax 905.844.2635

H0569400B

Litho in U.S.A. © Waterpik Technologies 0505

Summary of Contents for Slide Backwash Valve

Page 1: ...and Operation Manual FOR YOUR SAFETY This product must be installed and serviced by authorized personnel qualified in pool spa installation and maintenance Improper installation and or operation will...

Page 2: ......

Page 3: ...e Valve without unions and p n 8044 Versa Coupler Kit The Slide Valve is a two position valve The valve handle must be fully extended or fully depressed This valve can not be throttled To operate the...

Page 4: ...044 See Figure 4 If using the Slide Valve with a Pentair filter use Pentair Pool Products Union Set 27002 and then proceed to section B If using a Sta rite filter use Sta Rite Union Set PKGM188 then p...

Page 5: ...ters Ensure that the Slide Valve handle is fully depressed handle and piston pushed all the way down Turn the handle until the stainless steel pin on the piston locks into the position bracket Sand Fi...

Page 6: ...un the system until the waste water runs clean 5 Turn off the system pump s 6 Return the Slide Valve handle to the normal operating position see Section 3 7 Turn on system pump s and check for normal...

Page 7: ...union nut 10 Return the Slide Valve handle to the normal operating position see Section 3 11 Turn on system pump s and check for normal water flow Section 6 Winterizing Lid O ring Shaft O ring Top Bl...

Page 8: ...n Tail Piece Roll Pin Handle 1 Roll Pin Shaft 13 16 Index Plate Lid 1 1 1 2 1 1 1 R0442100 2 Shaft Replacement Kit Shaft Handle Roll Pin Handle 1 Roll Pin Shaft 13 16 Index Plate Lid Lid Union Nut O r...

Page 9: ...Page 9 NOTES...

Page 10: ...Page 10 NOTES...

Page 11: ......

Page 12: ...at water flow rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combusti...

Reviews: