-  Place the bracket, with the blower relay, in  

  position by aligning the holes in the bracket 

  with the holes on the back panel where the 

  pump relay was mounted. Place the pump relay 

  over the bracket and use the screws removed 

  earlier to secure the bracket and the pump relay  

  to the back panel (see Figure 6).

Figure 3.  Remove the Cover of the High Voltage  

 

     Assembly

Figure 4.  Mount the Blower Relay 

Figure 5.  Use the Mounting Bracket if the Filter  

 

  Pump Relay is Mounted in the High  

 

  Voltage Assembly

Figure 6.  Mount the Bracket Under the Filter Pump  

 

  Relay

Summary of Contents for R0412001

Page 1: ...u with all of the major compo nents of the system that you will need to install the side wall vent Due to the different possible configurations for venting we do not supply the vent pipe elbows tees w...

Page 2: ...nfiguration consists of an initial vertical section of vent pipe see Figure 2 Either configuration must meet the following constraints 1 The draft hood must be connected directly to the heater as per...

Page 3: ...he heater with power 2 Remove the heater door 3 Locate the common terminal on the transformer There will be a yellow wire with a piggy back terminal attached to the transformer and a green wire with a...

Page 4: ...mp relay over the bracket and use the screws removed earlier to secure the bracket and the pump relay to the back panel see Figure 6 Figure 3 Remove the Cover of the High Voltage Assembly Figure 4 Mou...

Page 5: ...or bracket included in the kit must be installed to deflect the air around the igniter allowing it to heat enough to ignite the gas The air deflector bracket is not needed on the mod el LD heater beca...

Page 6: ...he side of the heater using a conduit connector and nut 3 Strip the insulation from each of the wires that will lead to the UC1 controller about 1 2 from the end 4 Locate the yellow wire installed on...

Page 7: ...LD LJ Side Wall Vent Kit Instructions Page 7 Figure 10 Wiring Diagram for Connecting a Model LD Heater to a Side Wall Power Venter F2 F1...

Page 8: ...Page 8 Figure 11 Wiring Diagram for Connecting a Model LJ Heater to a Side Wall Power Venter...

Page 9: ...ler NOTE Power connection to the controller requires a three 3 conductor copper wire harness that is run in a conduit from the power supply to the con troller These components must be supplied by the...

Page 10: ...tch es must remain in the off down position see Figure 12 3 5 2 Jumper Placement in the UC1 Controller Installed on a Model LD Heater The Jandy LD heater uses a 24V signal to activate the power venter...

Page 11: ...peration and enables the heater to begin its ignition se quence 3 When the igniter is hot enough the gas valve opens and burner ignition takes place 4 When the call for heat ends the burners are shut...

Page 12: ...EDUCER 9 X 6 FOR MODEL 400 1 11 WIRE NUTS 3 3 3 12 YELLOW WIRE ASSEMBLY MODEL LD ONLY 1 1 1 13 PURPLE WIRE ASSEMBLY 1 1 1 14 1 4 DOUBLE MALE X 1 4 FEMALE CONNECTOR MODEL LD ONLY 1 1 1 15 BLOWER RELAY...

Reviews: