Section 3. Installing the Deck 

Canister

NOTE

 

  Prior to installing the Jandy laminar jet deck 

canister, locate the jet opening (slot) in the 
deck canister cover. Make sure that this 
opening is pointing towards the desired target 
location in the pool. Use the water stand pipe 
as a reference (see Figure 3). Determining 
the orientation of the deck canister will also 
establish where to place the plumbing and fi ber 
optic conduit.

NOTE

   The deck canister lid can only rotate 

approximately 90 degrees to the left or the right. 
Therefore, make sure that the deck canister is 
positioned towards the desired target location

 

prior

 to completing the installation. 

3.1 In-Deck 

Installation

1. 

Dig the hole for the deck canister approximately 
24 inches deep and 18 inches in diameter. This will 
ensure enough room for positioning the canister 
and laying out the plumbing. This depth also 
allows for the addition of a layer of pea gravel (1/8 
to 1/4 size) for stability and additional drainage. 
Refer to Figure 4 for deck canister dimensions.

2. 

Set the deck canister in the hole. The top edge 
of the lid/collar should be flush with the finished 
deck, after the deck material is poured.

NOTE

  To ensure that the canister stays upright while 

installing

 and

 leveling the unit, place a 6 inch 

piece of 1 inch PVC pipe in the construction 
support stake-up socket located on the bottom 
of the canister (see Figure 5).

Figure 3.  Laminar Jet Deck Canister Schematic

Figure 4.  Deck Canister Dimensions

2.50 in.

18.18 in.

21.78 in.

12 in.

13.75 in.

3. 

Level the deck canister. To hold the canister in 
place while the deck is poured, secure the canister 
by tying it with tie wire to the steel framework of 
the deck.  To mount level, horizontal rebar hooks 
and vertical rebar sockets are provided around the 
outside of the canister. See Figure 5.

4. 

Plumb the incoming filtered water supply to the 
1 inch hub located on the side of the deck canister 
marked “Inlet” (see Figure 6). The filtered water 
supply must include a check valve (see Figures 1 
and 2).

5. 

Plumb the conduit for the fiber LED cable to the 
3/4 inch socket located either side of the deck 

Horizontal Rebar

Horizontal Rebar

Hooks (4 Places)

Vertical Rebar

Vertical Rebar

Sockets (4 Places)

Stake-Up Socket

  1” PVC 
Stand Pipe

Figure 5.  Deck Canister Rebar Hooks and Sockets

Deck Canister

Water Output

Deck Canister 
Lid with Slot

Deck Material

Deck Material

Laminar Jet
Assembly

Deck Canister Lid 
Adjustable Collar

1" Laminar Jet 
Water Supply 

1½" Drain 
Line

¾" Electrical 
Conduit

Water Inlet to Jet 
Assembly

1" PVC Stand 
Pipe 

Summary of Contents for Laminar Jet

Page 1: ...sional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death This...

Page 2: ......

Page 3: ...inar Jet with LED Lights 9 4 3 1 Wiring to an AquaLink RS Control System 9 4 3 2 Wiring to a Time Clock 10 4 3 3 Wiring to a Switch 10 4 4 Twelve 12 Volt Transformer Installation 10 Section 5 Laminar...

Page 4: ...te an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specif...

Page 5: ...ch laminar jet requires a 1 to 2 inches PVC main feed line with 1 inch PVC entering the deck canister A check valve is also required and should be placed as far from the deck canister as possible to m...

Page 6: ...mbing Loop C Inlet Lines to Laminar Jet Deck Canister Maximum 6 Lines per Plumbing Loop D Bypass Bleed Off Line A Main Feed Line Check Valve Jandy 3 Port Valve P N 4715 if A is 1 or P N 4717 if A is 2...

Page 7: ...red NOTE To ensure that the canister stays upright while installing and leveling the unit place a 6 inch piece of 1 inch PVC pipe in the construction support stake up socket located on the bottom of t...

Page 8: ...n the bottom of the canister see Figure 5 3 Set the deck canister in the hole The canister should be approximately 1 2 inches above the finished grade in the planter NOTE Unlike the in deck installati...

Page 9: ...ain relief over cord jacket and connect all three 3 wires to the corresponding circuit wires in the low voltage transformer Install the low voltage transformer cover 5 Turn on main switch or circuit b...

Page 10: ...laminar jets with one 200 watt transformer To ensure maximum safety the transformer used to power the laminar jet with LED lights must be one that is listed by a Nationally Recognized Testing Laborato...

Page 11: ...supplied with the illuminator Section 6 Starting the System 6 1 Install Jet Assembly 1 Disconnect the pressure cap that is installed on the flexible PVC hose NOTE The system should be pressure tested...

Page 12: ...the light ON The first time the light is turned on the color sequence begins with the Alpine White To change the color turn the light OFF and then ON within three 3 seconds Continue turning OFF and ON...

Page 13: ...erence Increased water stream flow will cause a greater disturbance of the laminar jet stream and create a more intense light 1 Use the light intensity adjustment screw attached to the scratcher to ad...

Page 14: ...the flexible hose attached to the deck canister The laminar jet can then be replaced in the deck canister or may be removed to a storage location If left in the deck canister tape over the slot openin...

Page 15: ...Page 15 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10 10 2 Exploded View...

Page 16: ...factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals up...

Reviews: