NOTE

  The laminar jet with LED light operates only on 12 

volts AC. A suitable 120-volt/12-volt stepdown AC 
transformer MUST be used. Refer to 

Section 4.4 

of 

this manual for further important details.

4.3.2  Wiring to a Time Clock

The laminar jet with LED lights can be wired into a basic 

time clock to automatically turn on the laminar jet with 

LED lights at a predesignated time. Refer to Figure 8 

to connect the laminar jet with LED lights into the time 

clock.

4.3.3  Wiring to a Switch

The laminar jet with LED lights can be wired into a switch 
to manually turn on/off the lights. Refer to Figure 9 to 
connect the laminar jet with LED lights into the switch.

4.4 

Twelve (12) Volt Transformer 
Installation

The laminar jet with LED lights requires the use of a 
120/12VAC-100 watt low voltage lighting transformer. 

NOTE 

  For optimum performance Zodiac Pool Systems, 

Inc. recommends using one transformer per 12-
volt laminar jet. However, it is possible to power up 
to 4 laminar jets with one 200 watt transformer.

To ensure maximum safety, the transformer used to power 
the laminar jet with LED lights must be one that is listed 
by a Nationally Recognized Testing Laboratory (NRTL) 
for the application.

NOTE 

  If the pool already has a low voltage transformer 

powering the pool and/or spa lights, do not use 
the same transformer to power the laminar jet with 
LED lights.  This is to ensure that the laminar jet’s 
LED lights are only turned on when the laminar jet 
pump is running.

Black
White

Green

Ground

Neutral

120 VAC

Power Supply

Black

White

Green

JUNCTION

BOX

Laminar Jet 

with 

LED Light

120V/12V

Transformer

Black
White

Green

Clock 

Motor

Ground

Ground

Neutral

Line

A

1

2

Black

White

Green

120 V

SUPPL

Y

Black

White

Green

JUNCTION

BOX

Laminar Jet 

with 

LED Light

120V/12V

Transformer

Black
White

Green

Ground

Neutral

Line

120 V Supply

Black

White

Green

SWITCH

Black

White

Green

JUNCTION

BOX

Laminar Jet 

with 

LED Light

120V/12V

Transformer

Black

White

Green

Figure 7.  12-Volt Laminar Jet with LED Light 

Wiring Diagram

Figure 8.  Wiring the Laminar Jet with LED Light 

to a Time Clock

Figure 9.  Wiring the Laminar Jet with LED Light 

to a Switch

Summary of Contents for Laminar Jet

Page 1: ...sional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death This...

Page 2: ......

Page 3: ...inar Jet with LED Lights 9 4 3 1 Wiring to an AquaLink RS Control System 9 4 3 2 Wiring to a Time Clock 10 4 3 3 Wiring to a Switch 10 4 4 Twelve 12 Volt Transformer Installation 10 Section 5 Laminar...

Page 4: ...te an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specif...

Page 5: ...ch laminar jet requires a 1 to 2 inches PVC main feed line with 1 inch PVC entering the deck canister A check valve is also required and should be placed as far from the deck canister as possible to m...

Page 6: ...mbing Loop C Inlet Lines to Laminar Jet Deck Canister Maximum 6 Lines per Plumbing Loop D Bypass Bleed Off Line A Main Feed Line Check Valve Jandy 3 Port Valve P N 4715 if A is 1 or P N 4717 if A is 2...

Page 7: ...red NOTE To ensure that the canister stays upright while installing and leveling the unit place a 6 inch piece of 1 inch PVC pipe in the construction support stake up socket located on the bottom of t...

Page 8: ...n the bottom of the canister see Figure 5 3 Set the deck canister in the hole The canister should be approximately 1 2 inches above the finished grade in the planter NOTE Unlike the in deck installati...

Page 9: ...ain relief over cord jacket and connect all three 3 wires to the corresponding circuit wires in the low voltage transformer Install the low voltage transformer cover 5 Turn on main switch or circuit b...

Page 10: ...laminar jets with one 200 watt transformer To ensure maximum safety the transformer used to power the laminar jet with LED lights must be one that is listed by a Nationally Recognized Testing Laborato...

Page 11: ...supplied with the illuminator Section 6 Starting the System 6 1 Install Jet Assembly 1 Disconnect the pressure cap that is installed on the flexible PVC hose NOTE The system should be pressure tested...

Page 12: ...the light ON The first time the light is turned on the color sequence begins with the Alpine White To change the color turn the light OFF and then ON within three 3 seconds Continue turning OFF and ON...

Page 13: ...erence Increased water stream flow will cause a greater disturbance of the laminar jet stream and create a more intense light 1 Use the light intensity adjustment screw attached to the scratcher to ad...

Page 14: ...the flexible hose attached to the deck canister The laminar jet can then be replaced in the deck canister or may be removed to a storage location If left in the deck canister tape over the slot openin...

Page 15: ...Page 15 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10 10 2 Exploded View...

Page 16: ...factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals up...

Reviews: