Jandy Laminar Jet Installation And Operation Manual Download Page 13

Page 13

NOTE

 

When the light is turned OFF for more than 
seven (7) seconds, it will remain in the color set 
that is currently active. When the light is turned 
back ON, the light will be on the same color set.

7.2 

To Reset to the Beginning of the 
Color Sequence

Turn the light OFF, wait four (4) to six (6) seconds, then 
turn ON, the light will return to the beginning of the 
color cycle (Alpine White). 

NOTE

 

If an AquaLink

®

 RS control system is being 

used the color set can be selected using the 
controller.

NOTE

 

To synchronize colors on multiple Jandy 
WaterColors light systems and Jandy Laminar 
Jets with LED Lights wired to separate 
switches, preform the above actions on all of the 
switches simultaneously. All Jandy WaterColors 
lights and Jandy laminar jet with LED lights will 
synchronize automatically if activated by the 
same switch. No other accessories are required.

Section 8. Light Intensity Set Up

8.1 

Light Intensity Adjustment Set 

NOTE

 

The LED light intensity can be adjusted to your 
preference.  Increased water stream fl ow will 
cause a greater disturbance of the laminar jet 
stream and create a more intense light.

1. 

Use the light intensity adjustment screw attached 
to the scratcher to adjust the light intensity as 
shown in Figure 12.

2. 

To increase the light intensity, turn the screw 
counter-clockwise to increase the water stream 
coming out of the scratcher.  This water stream 
disturbs the surface of the laminar jet flow causing 
an increase in the light intensity.

NOTE

 

Laminar jets are sensitive to wind, earth 
movement and equipment vibration. Secure 
the laminar jet and deck canister to minimize 
vibration. Periodic stream distortion caused 
by pump vibrations and motor electrical 
fl uctuations is normal and not indicative of a 
nozzle defect. Also, occasionally a nozzle will 
“burp” due to pumped air collecting in the nozzle 
body. This is normal and will occur until all air 
is purged from the piping system. Trapped air 
can also cause slight distortion in water action. 
It is imperative that all air is removed to ensure 
proper water feature operation.

Figure 12.  Scratcher Assembly and Light Intensity 

Adjustment Screw

Scratcher

Light Intensity 
Adjustment Screw 

Screwdriver

Summary of Contents for Laminar Jet

Page 1: ...sional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death This...

Page 2: ......

Page 3: ...inar Jet with LED Lights 9 4 3 1 Wiring to an AquaLink RS Control System 9 4 3 2 Wiring to a Time Clock 10 4 3 3 Wiring to a Switch 10 4 4 Twelve 12 Volt Transformer Installation 10 Section 5 Laminar...

Page 4: ...te an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specif...

Page 5: ...ch laminar jet requires a 1 to 2 inches PVC main feed line with 1 inch PVC entering the deck canister A check valve is also required and should be placed as far from the deck canister as possible to m...

Page 6: ...mbing Loop C Inlet Lines to Laminar Jet Deck Canister Maximum 6 Lines per Plumbing Loop D Bypass Bleed Off Line A Main Feed Line Check Valve Jandy 3 Port Valve P N 4715 if A is 1 or P N 4717 if A is 2...

Page 7: ...red NOTE To ensure that the canister stays upright while installing and leveling the unit place a 6 inch piece of 1 inch PVC pipe in the construction support stake up socket located on the bottom of t...

Page 8: ...n the bottom of the canister see Figure 5 3 Set the deck canister in the hole The canister should be approximately 1 2 inches above the finished grade in the planter NOTE Unlike the in deck installati...

Page 9: ...ain relief over cord jacket and connect all three 3 wires to the corresponding circuit wires in the low voltage transformer Install the low voltage transformer cover 5 Turn on main switch or circuit b...

Page 10: ...laminar jets with one 200 watt transformer To ensure maximum safety the transformer used to power the laminar jet with LED lights must be one that is listed by a Nationally Recognized Testing Laborato...

Page 11: ...supplied with the illuminator Section 6 Starting the System 6 1 Install Jet Assembly 1 Disconnect the pressure cap that is installed on the flexible PVC hose NOTE The system should be pressure tested...

Page 12: ...the light ON The first time the light is turned on the color sequence begins with the Alpine White To change the color turn the light OFF and then ON within three 3 seconds Continue turning OFF and ON...

Page 13: ...erence Increased water stream flow will cause a greater disturbance of the laminar jet stream and create a more intense light 1 Use the light intensity adjustment screw attached to the scratcher to ad...

Page 14: ...the flexible hose attached to the deck canister The laminar jet can then be replaced in the deck canister or may be removed to a storage location If left in the deck canister tape over the slot openin...

Page 15: ...Page 15 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10 10 2 Exploded View...

Page 16: ...factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals up...

Reviews: